15 / 22 page ![]() AXL E ETH DI8 DO4 2A M12 6P 8553_en_03 PHOENIX CONTACT 15 11 Monitoring Monitoring functions with different features are available for monitoring Ethernet communication. – Modbus connection monitoring – Process data watchdog By default upon delivery, the process data watchdog is de- activated. By default upon delivery, the process data watchdog is de- activated. If the timeout period expires for one or both mechanisms, the OUT process data is blocked. The parameterized substi- tute value behavior of the outputs is performed. The error is indicated by the NET LED (red on). During the Net Fail state, the OUT process data can continue to be up- dated by the application. Following a Net Fail reset, substitute values are then re- placed by the latest process data. Function of the process data watchdog A process data watchdog is integrated into the device to avoid uncontrolled setting/resetting of outputs in the event of an error. If outputs are set, the controlling process must be able to ac- cess the device. In the event of an error, e.g., network cable interrupted or function error in the controlling process, the device can re- spond appropriately via the process data watchdog. When activating the process data watchdog, it is started by the first write process and the next write process is expected within the timeout period. During error-free operation, the write process is performed during the timeout period and the watchdog is restarted (triggered). 11.1 Net fail If there is no triggering during the timeout period, an error oc- curred. Two responses follow: – All outputs are set to the configured substitute value. –The Net Fail signal is set (NET LED is red and bit 1 in status register 7996 is set). For safety reasons, the user cannot stop the watchdog once it has been activated. If the user terminates the controlling application, the watch- dog is not triggered. When the timeout period elapses, the Net Fail signal is set, and the parameterized substitute value behavior is performed. After the watchdog has performed its task, the outputs are only enabled again after acknowledgment. 11.2 Configuring the process data watchdog To activate the watchdog, specify the desired timeout period in the range of 200 ms and 65,000 ms. In order to deactivate the watchdog, specify the 0 ms time- out period. You have the following options for changing the timeout pe- riod: – Web-based management – Modbus register 2000 Mechanism Monitoring Modbus connection moni- toring Client application Modbus channels Ethernet connection Process data watchdog Client application Ethernet connection Process data exchange By default upon delivery, the process data watchdog is deactivated; timeout period = 0 ms. Reading calls do not trigger the process data watchdog. When the error is acknowledged, the watch- dog is restarted. This means that it must be triggered during the timeout period, otherwise an error is detected again. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |