| Electronic Components Datasheet Search |
|
970B Datasheet(PDF) 3 Page - MKS Instruments. |
|
|
|||||||||||||||||||||||||||||
970B Datasheet(HTML) 3 Page - MKS Instruments. |
|
3 / 4 page ![]() Specifications Series 971B Series 972B Series 974B Sensor Type Cold Cathode Cold Cathode / MicroPirani (MEMS Thermal Conductivity) Cold Cathode / MicroPirani (MEMS Thermal Conductivity) / Piezo Differential (MEMS Diaphragm) Measuring Range Absolute 1 x 10-8 Torr to 5 x 10-3 Torr 1 x 10-8 Torr to Atmosphere 1 x 10-8 Torr to 1500 Torr Measuring Range Differential not available not available -760 to +760 Torr Set Point Range Absolute 1 x 10-8 Torr to 5 x 10-3 Torr 1 x 10-8 Torr to Atmosphere 1 x 10-8 Torr to 1000 Torr Set Point Range Differential not available not available -760 to +100 Torr Calibration Gas Nitrogen Nitrogen Nitrogen Operating Temperature Range 0° to 40°C (32° to 104°F) 0° to 40°C (32° to 104°F) 0° to 40°C (32° to 104°F) Maximum Bakeout Temperature 80°C (176°F), non-operating 80°C (176°F), non-operating 80°C (176°F), non-operating Digital Communications RS485 or RS232 RS485, RS232 or EtherCAT RS485 or RS232 Electrical Connectors RS232/RS485/Analog EtherCAT (972B only) 15-pin D-subminiature male 15-pin D-subminiature male 15-pin D-subminiature male Two (2) RJ45 female 15-pin D-subminiature male Controls Pressure units, baud rate, address, factory default, user tag, RS485 test, gas correction; set point functions: value, hysteresis, direction, HV enable, protect, control set point, gas type Pressure units, baud rate, address, factory default, user tag, RS485 test, gas correction; set point functions: value, hysteresis, direction, HV enable, protect, control set point, gas type Pressure units, baud rate, address, factory default, user tag, RS485 test, gas correction; set point functions: value, hysteresis, direction, HV enable, protect, control set point, gas type Status Pressure reading and units, set point, transducer temperature, user tag, model, device type, serial number, firmware and hardware versions Pressure reading and units, set point, transducer temperature, user tag, model, device type, serial number, firmware and hardware versions Pressure reading and units, set point, transducer temperature, user tag, model, device type, serial number, firmware and hardware versions Analog Output (Absolute Pressure) 0.5 VDC / decade 0.5 VDC / decade 0.5 VDC / decade Relays, Optional RS232/RS485 3 relays, SPST 3 relays, SPST 3 relays, SPST Relay Contact Rating 1 A @ 30VAC/DC, resistive 1 A @ 30VAC/DC, resistive 1 A @ 30VAC/DC, resistive Power Requirements 9-30 VDC, 2 W 9-30 VDC, 2 W 9-30 VDC, 2 W Accuracy (Typical) Combined Absolute 5 x 10-8 Torr to 10-3 ± 30% of reading 5 x 10-8 Torr to 10-3 ± 30% of reading 10-3 to 100 ±5% of reading 5 x 10-8 Torr to 10-3 ± 30% of reading 10-3 to 50 Torr ±5% of reading 50 to 1000 Torr ± 1% of reading Repeatability (Typical) Combined Absolute 5 x 10-8 Torr to 10-3 ± 30% of reading 5 x 10-8 Torr to 10-3 ± 30% of reading 10-3 to 100 ±2% of reading 5 x 10-8 Torr to 10-3 ± 30% of reading 10-3 to 50 ±2% of reading 50 to 1000 Torr ± 1% of reading Accuracy (Typical) 1 Differential not available not available -10 to +10 Torr ±10% of reading -100 to -10 Torr ±8% of reading -760 to -100 Torr ±1% of reading +10 to 100 Torr ±5% of reading Repeatability (Typical) 1 Differential not available not available -760 to +10 Torr ±1% of reading Zero Stability (Typical) 1 Differential not available not available ±0.1% of Full Scale (F.S. = 760 Torr) Overpressure Limit 1500 Torr 1500 Torr 1500 Torr Installation Orientation Any Any Any Internal Volume 21 cm3 21 cm3 21 cm3 Materials Exposed to Vacuum 304 and 403 stainless steel, Viton®, Cu-Ni and Ag-Cu alloy, ceramic, titanium 304 and 403 stainless steel, silicon, SiO 2, SiN4, gold, Viton®, epoxy resin, ceramic, titanium 304 and 403 stainless steel, silicon, SiO 2, SiN4, gold, Viton®, epoxy resin, ceramic, titanium Electronic Casing 304 stainless steel 304 stainless steel 304 stainless steel Weight (with NW25 KF Flange) 12.7 oz (360 g) 12.7 oz (360 g) 12.7 oz (360 g) Compliance CE CE, ETG.5003.2080 Vacuum Pressure Gauge CE 1 Note: Accuracy and repeatability are typical values measured with Nitrogen gas at ambient temperature after zero adjustment. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |