5 / 12 page ![]() LM75 http://onsemi.com 5 programmed in the Fault Queue. Up to a six–cycle ”filter” may be selected. See Register Set and Programmer’s Model. Serial Port Operation The Serial Clock input (SCL) and bidirectional data port (SDA) form a 2–wire bidirectional serial port for programming and interrogating the LM75. The following conventions are used in this bus scheme: LM75 Serial Bus Conventions Term Explanation Transmitter The device sending data to the bus. Receiver The device receiving data from the bus. Master The device which controls the bus: initiat- ing transfers (START), generating the clock, and terminating transfers (STOP). Slave The device addressed by the master. Start A unique condition signaling the beginning of a transfer indicated by SDA falling (High–Low) while SCL is high. Stop A unique condition signaling the end of a transfer indicated by SDA rising (Low – High) while SCL is high. ACK A Receiver acknowledges the receipt of each byte with this unique condition. The Receiver drives SDA low during SCL high of the ACK clock–pulse. The Master pro- vides the clock pulse for the ACK cycle. NOT Busy When the bus is idle, both SDA & SCL will remain high. Data Valid The state of SDA must remain stable dur- ing the High period of SCL in order for a data bit to be considered valid. SDA only changes state while SCL is low during nor- mal data transfers. (See Start and Stop conditions) All transfers take place under control of a host, usually a CPU or microcontroller, acting as the Master, which provides the clock signal for all transfers. The LM75 always operates as a Slave. This serial protocol is illustrated in Figure 2. All data transfers have two phases; and all bytes are transferred MSB first. Accesses are initiated by a start condition (START), followed by a device address byte and one or more data bytes. The device address byte includes a Read/Write selection bit. Each access must be terminated by a Stop Condition (STOP). A convention called Acknowledge (ACK) confirms receipt of each byte. Note that SDA can change only during periods when SCL is LOW (SDA changes while SCL is HIGH are reserved for Start and Stop Conditions). Start Condition (START) The LM75 continuously monitors the SDA and SCL lines for a start condition (a HIGH to LOW transition of SDA while SCL is HIGH), and will not respond until this condition is met. (See Timing Diagram) Address Byte Immediately following the Start Condition, the host must next transmit the address byte to the LM75. The four most significant bits of the Address Byte (A6, A5, A4, A3) are fixed to 1001(B). The states of A2, A1 and A0 in the serial bit stream must match the states of the A2, A1 and A0 address inputs for the LM75 to respond with an Acknowledge (indicating the LM75 is on the bus and ready to accept data). The eighth bit in the Address Byte is a Read–Write Bit. This bit is a 1 for a read operation or 0 for a write operation. Acknowledge (ACK) Acknowledge (ACK) provides a positive handshake between the host and the LM75. The host releases SDA after transmitting eight bits then generates a ninth clock cycle to allow the LM75 to pull the SDA line LOW to acknowledge that it successfully received the previous eight bits of data or address. Data Byte After a successful ACK of the address byte, the host must next transmit the data byte to be written or clock out the data to be read. (See the appropriate timing diagrams.) ACK will be generated after a successful write of a data byte into the LM75. Stop Condition (STOP) Communications must be terminated by a stop condition (a LOW to HIGH transition of SDA while SCL is HIGH). The Stop Condition must be communicated by the transmitter to the LM75. (See Timing Diagram) Power Supply To minimize temperature measurement error, the LM75DM–33 is factory calibrated at a supply voltage of 3.3V ±5% and the LM75DM–50 is factory calibrated at a supply voltage of 5V ±5%. Either device is fully operational over the power supply voltage range of 2.7V to 5.5V, but with a lower measurement accuracy. The typical value of this power supply–related error is ±2°C. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |