| Electronic Components Datasheet Search |
|
S5000VSA Datasheet(PDF) 57 Page - Intel Corporation |
|
|
|||||||||||||||||||||||||||||
S5000VSA Datasheet(HTML) 57 Page - Intel Corporation |
|
57 / 86 page ![]() Intel® Server Board S5000VSA TPS Design and Environmental Specifications Revision 1.4 Intel order number – D36978-006 57 8.3.2 Grounding The ground of the pins of the power supply output connector provides the power return path. The output connector ground pins are connected to safety ground (power supply enclosure). The power supply must be provided with a reliable protective earth ground. All secondary circuits are connected to protective earth ground. Resistance of the ground returns to chassis does not exceed 1.0 m Ω. This path may be used to carry DC current. 8.3.3 Standby Outputs The 5 VSB output is present when an AC input greater than the power supply turn on voltage is applied. 8.3.4 Remote Sense The power supply has remote sense return (ReturnS) to regulate out ground drops for all output voltages; +3.3 V, +5 V, +12 V1, +12 V2, -12 V, and 5 VSB. The power supply uses remote sense to regulate out drops in the system for the +3.3 V, +5 V, and 12 V1 outputs. The remote sense input impedance to the power supply is greater than 200 Ω on 3.3 VS, 5 VS. This is the value of the resistor connecting the remote sense to the output voltage internal to the power supply. Remote sense is able to regulate out a minimum of 200 mV drop on the +3.3 V output. The remote sense return (ReturnS) is able to regulate out a minimum of 200 mV drop in the power ground return. The current in any remote sense line is less than 5 mA to prevent voltage sensing errors. The power supply operates within specification over the full range of voltage drops from the power supply’s output connector to the remote sense points. 8.3.5 Voltage Regulation The power supply output voltages are within the following voltage limits when operating at steady state and dynamic loading conditions. These limits include the peak-peak ripple/noise. All outputs are measured with reference to the return remote sense signal (ReturnS). The 5 V, 12 V1, 12 V2, –12 V and 5 VSB outputs are measured at the power supply connectors referenced to ReturnS. The +3.3 V is measured at the remote sense signal (3.3 VS) located at the signal connector. Table 43. Voltage Regulation Limits Parameter Tolerance MIN NOM MAX Units + 3.3V - 5% / +5% +3.14 +3.30 +3.46 Vrms + 5V - 5% / +5% +4.75 +5.00 +5.25 Vrms + 12V1 - 5% / +5% +11.40 +12.00 +12.60 Vrms + 12V2 - 5% / +5% +11.40 +12.00 +12.60 Vrms - 12V - 5% / +9% -11.40 -12.00 -13.08 Vrms + 5VSB - 5% / +5% +4.75 +5.00 +5.25 Vrms |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |