7 / 28 page ![]() 6.7 Safety-Related Certifications VDE CSA UL CQC TUV Certified according to DIN VDE V 0884-11:2017-01 Certified according to IEC 60950-1, IEC 62368-1 and IEC 60601-1 Recognized under UL 1577 Component Recognition Program Certified according to GB4943.1-2011 Certified according to EN 61010-1:2010/A1:2019, EN 60950- 1:2006/A2:2013 and EN 62368-1:2014 Maximum transient isolation voltage, 4242 VPK (D-8); Maximum repetitive peak isolation voltage 637 VPK (D-8); Maximum surge isolation 5000 VPK (D-8) D-8: 400 VRMS basic insulation per CSA 60950-1-07+A1+A2, IEC 60950-1 2nd Ed.+A1+A2, CSA 62368-1- 14 and IEC 62368-1:2014, (pollution degree 2, material group 2) D-8: Single protection, 3000 VRMS D-8: Basic Insulation, Altitude ≤ 5000 m, Tropical Climate, 250 VRMS maximum working voltage 3000 VRMS (D-8) Reinforced insulation per EN 61010- 1:2010/A1:2019 up to working voltage 300 VRMS (D-8) 3000 VRMS (D-8) Reinforced insulation per EN 60950- 1:2006/A2:2013 and EN 62368-1:2014 up to working voltage of 400 VRMS (D-8) Certification planned Certification planned Certification planned Certification planned Certification planned 6.8 Safety Limiting Values Safety limiting intends to minimize potential damage to the isolation barrier upon failure of input or output circuitry. PARAMETER TEST CONDITIONS MIN TYP MAX UNIT D-8 PACKAGE IS Safety input, output, or supply current(1) RθJA = 106.3 °C/W, VI = 5.5 V, TJ = 150°C, TA = 25°C, see TBD 214 mA RθJA = 106.3 °C/W, VI = 3.6 V, TJ = 150°C, TA = 25°C, see TBD 327 PS Safety input, output, or total power(1) RθJA = 106.3 °C/W, TJ = 150°C, TA = 25°C 1176 mW TS Safety temperature(1) 150 °C (1) The maximum safety temperature, TS, has the same value as the maximum junction temperature, TJ, specified for the device. The IS and PS parameters represent the safety current and safety power respectively. The maximum limits of IS and PS should not be exceeded. These limits vary with the ambient temperature, TA. The junction-to-air thermal resistance, RθJA, in the table is that of a device installed on a high-K test board for leaded surface-mount packages. Use these equations to calculate the value for each parameter: TJ = TA + RθJA × P, where P is the power dissipated in the device. TJ(max) = TS = TA + RθJA × PS, where TJ(max) is the maximum allowed junction temperature. PS = IS × VI, where VI is the maximum input voltage. www.ti.com ISO1640-Q1 SLLSFC3 – OCTOBER 2020 Copyright © 2020 Texas Instruments Incorporated Submit Document Feedback 7 Product Folder Links: ISO1640-Q1 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |