| Electronic Components Datasheet Search |
|
EVDP610 Datasheet(PDF) 4 Page - IXYS Corporation |
|
|
|||||||||||||||||||||||||||||
EVDP610 Datasheet(HTML) 4 Page - IXYS Corporation |
|
4 / 6 page ![]() 4 EVDP610 3.1.1 Reset IXDP610 This toggle button will reset the EVDP610 board and the GUI back into their initial states. If the EVDP610 board’s power has been cycled this button can be used to reset the GUI software. If for any reason the hardware and software disagree this button can be used to reinitialize the hardware and the software into the same state (the user will lose the current settings of the board). 3.1.2 Read IXDP610 Status This toggle button will read the status of the EVDP610 board. It will update the GUI to the current Pulse Set- tings, Dead Time Settings, Lock Settings, and Output Settings. If for any reason the hardware and software disagree this button can be used to read what the hardware is doing and update the software. 3.1.3 Lock This button will “lock” the control register of the IXDP610, which will not allow the dead-time period, clock divide, resolution or the stop bit to be changed. Hitting this button again, or hitting the RESET IXDP610 button will unlock the IXDP610. 3.1.4 Serial Settings These buttons control the baud rate and the COM port selection (1 – 4). *Note: Baud rate is not variable and will remain dimmed. 3.1.5 Clock Settings The CLOCK DIVIDE button will cause the input clock of the IXDP610 chip to be internally divided by 1 or by 2. The clock select button allows the microprocessor to control the input clock to the IXDP610, which can then be variably changed by the GUI. The output frequency ring allows the user to select the frequency of the output of the IXDP610 from 1 – 50 Hz. When the clock is selected the GUI will prompt the user to make sure of the correct jumper settings. 3.1.6 Pulse Settings The Resolution toggle button allows the user to switch between seven-bit and eight-bit resolution on the EVDP610 board. The pulse width can be written to the IXDP610 by either the Duty Cycle or Pulse Width. One of these must be selected by the toggle switch. When Duty Cycle is selected and the user has entered a number into the Duty Cycle textbox the pulse width textbox will be updated with the actual number written into the pulse width latch of the IXDP610. Duty Cycle and Pulse Width are always calculated with respect to resolution, meaning if the value entered into Duty Cycle was 50%, in 7-bit mode the pulse width number will be 64 where as in 8-bit resolution the pulse width number will be 128. The pulse width text box will display the actual number written to the pulse width latch, whereas the duty cycle is calculated based on the entered values. Be aware that if you were to enter 128 in the pulse width textbox, in 8-bit resolution, the output duty cycle will be 50%. If the IXDP610 is switched into 7-bit resolution the pulse width number will remain the same, yet the duty cycle now becomes 100% and the GUI and the hardware will be updated with these values. When the Read Pulse Settings button is pressed the evaluation board updates all pulse settings in the area. 3.1.7 Dead Time Dead Time can either be entered manually or with the arrow buttons to the side of the test box. The Read Dead Time button updates the GUI from the evaluation board. For a detailed discussion on dead time please see section 2.2.1 or the IXDP610 specification. 3.1.8 Outputs Enable The Outputs Enable button allows the user to turn on/off the outputs of the IXDP610. This button asserts the stop bit in the control latch of the IXDP610. When the out- puts are enabled the status LED located directly above the button will light. The LED will turn off when the Figure 6: The EVDP610 GUI GUI up to 390KHz (in 7-bit resolution). The external clock can be installed into the via on the board labeled TP3. 3.0 GUI GENERAL DESCRIPTION AND USE 3.1 The GUI After installing and starting up the GUI, figure 7 is the first screen that should appear. The Message box should read: “Welcome to the IXDP610 Test Environment” as seen in Figure 6. Be aware that when the GUI has established communication with the evaluation board, the GUI will reset the EVDP610 hardware to ensure that both the software and the hardware are in the same state. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |