47 / 50 page

8019AS.doc
2001-05-10
·ç¬R¥b¾ÉÅéªÑ¥÷¦³--¤½¥q
SPECIFICATION
RTL8019AS
47
T1
T3
T4
T5
T7
T8
T6
T2
AEN
SA0-11
IOCS16B
IORB,
IOWB
IOCHRDY
SD0-15 (read)
SD0-15 (write)
Symbol
Parameter
Min.
Typ.
Max.
Unit
T1
Host address valid to IOCS16B low
8
20
20
ns
T2
Host address invalid to IOCS16B high
4
30
--
ns
T3
IOCHRDY goes low from falling edge of
IORB or IOWB when wait state insertion is
needed.
--
50
50
ns
T4
Read data valid from falling edge of IORB or
IOWB when no wait state insertion is needed.
--
50
60
ns
T5
Read data valid to IOCHRDY high when wait
state is needed
25
--
--
ns
T6
Read data hold after IORB rising edge
10
30
30
ns
T7
Write data setup to IOWB rising edge
10
10
--
ns
T8
Write data hold from IOWB rising edge
10
10
--
ns