| Electronic Components Datasheet Search |
|
MAX1844 Datasheet(PDF) 14 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX1844 Datasheet(HTML) 14 Page - Maxim Integrated Products |
|
14 / 24 page ![]() Current-Limit Circuit (ILIM) The current-limit circuit employs a unique “valley” cur- rent-sensing algorithm (Figure 4). If the magnitude of the current-sense voltage at CS is above the current-limit threshold, the PWM is not allowed to initiate a new cycle. The actual peak current is greater than the current-limit threshold by an amount equal to the inductor ripple cur- rent. Therefore, the exact current-limit characteristic and maximum load capability are a function of the sense resistance, inductor value, and battery voltage. There is also a negative current limit that prevents exces- sive reverse inductor currents when VOUT is sinking cur- rent. The negative current-limit threshold is set to approximately 120% of the positive current limit and therefore tracks the positive current limit when ILIM is adjusted. The current-limit threshold is adjusted with an external resistor-divider at ILIM. A 1µA (min) divider current is recommended. The current-limit threshold adjustment range is from 25mV to 300mV. In the adjustable mode, the current-limit threshold voltage is precisely 1/10 the voltage seen at ILIM. The threshold defaults to 100mV when ILIM is connected to VCC. The logic threshold for switchover to the 100mV default value is approximately VCC - 1V. Carefully observe the PC board layout guidelines to ensure that noise and DC errors do not corrupt the cur- rent-sense signal seen by CS. Mount or place the IC close to the low-side MOSFET and sense resistor with short, direct traces, making a Kelvin sense connection to the sense resistor. In Figure 1, the Schottky diode (D1) provides a current path parallel to the Q2/RSENSE current path. Accurate current sensing demands D1 to be off while Q2 con- ducts. Avoid large current-sense voltages that, com- bined with the voltages across Q2, would allow D1 to conduct. If very large sense voltages are used, connect D1 in parallel with Q2. MOSFET Gate Drivers (DH, DL) The DH and DL drivers are optimized for driving moder- ate-sized high-side, and larger low-side power MOSFETs. This is consistent with the low duty factor seen in the notebook environment, where a large VBATT - VOUT differential exists. An adaptive dead-time circuit monitors the DL output and prevents the high-side FET from turning on until DL is fully off. There must be a low- resistance, low-inductance path from the DL driver to the MOSFET gate for the adaptive dead-time circuit to work properly; otherwise, the sense circuitry in the MAX1844 will interpret the MOSFET gate as “off” while there is actually still charge left on the gate. Use very short, wide traces measuring no more than 20 squares (50 to 100 mils wide if the MOSFET is 1 inch from the MAX1844). The dead time at the other edge (DH turning off) is deter- mined by a fixed 35ns (typ) internal delay. The internal pulldown transistor that drives DL low is robust, with a 0.5 Ω (typ) on-resistance. This helps pre- vent DL from being pulled up during the fast rise-time of the inductor node, due to capacitive coupling from the drain to the gate of the low-side synchronous-rectifier MOSFET. However, for high-current applications, there are still some combinations of high- and low-side FETs that will cause excessive gate-drain coupling, which can lead to efficiency-killing, EMI-producing shoot-through currents. This is often remedied by adding a resistor in series with BST, which increases the turn-on time of the high-side FET without degrading the turn-off time (Figure 5). POR, UVLO, and Soft-Start Power-on reset (POR) occurs when VCC rises above approximately 2V, resetting the fault latch and soft-start counter, and preparing the PWM for operation. Until VCC reaches 4.2V, VCC undervoltage lockout (UVLO) circuitry inhibits switching. DL is held low if overvoltage protec- tion is disabled, and held high if overvoltage protection is enabled. See the Output Overvoltage Protection section. When VCC rises above 4.2V, an internal digital soft-start timer begins to ramp up the maximum allowed current limit. The ramp occurs in five steps: 20%, 40%, 60%, 80%, and 100%; 100% current is available after 1.7ms ±50%. High-Speed Step-Down Controller with Accurate Current Limit for Notebook Computers 14 ______________________________________________________________________________________ BST +5V VIN 5 Ω DH LX MAX1844 Figure 5. Reducing the Switching-Node Rise Time |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |