Back Button X80141 Datasheet HTML 10Page - Renesas Technology Corp X80141 Datasheet HTML 11Page - Renesas Technology Corp X80141 Datasheet HTML 12Page - Renesas Technology Corp X80141 Datasheet HTML 13Page - Renesas Technology Corp X80141 Datasheet HTML 14Page - Renesas Technology Corp X80141 Datasheet HTML 15Page - Renesas Technology Corp X80141 Datasheet HTML 16Page - Renesas Technology Corp X80141 Datasheet HTML 17Page - Renesas Technology Corp X80141 Datasheet HTML 18Page - Renesas Technology Corp  
Zoom Inzoom in Zoom Outzoom out
 14 / 18 page
background image
X80140, X80141, X80142, X80143, X80144
FN8153 Rev 0.00
Page 14 of 18
January 20, 2005
Bus Interface Information
Interface Conventions
The device supports a bidirectional bus oriented protocol. The
protocol defines any device that sends data onto the bus as a
transmitter, and the receiving device as the receiver. The
device controlling the transfer is called the master and the
device being controlled is called the slave. The master always
initiates data transfers, and provides the clock for both transmit
and receive operations. Therefore, the devices in this family
operate as slaves in all applications.
It should be noted that the ninth clock cycle of the read
operation is not a “don’t care.” To terminate a read operation,
the master must either issue a STOP condition during the ninth
cycle or hold SDA HIGH during the ninth clock cycle and then
issue a STOP condition.
Serial Clock and Data
Data states on the SDA line can change only during SCL LOW.
SDA state changes during SCL HIGH are reserved for
indicating START and STOP conditions. See Figure 11.
Serial START Condition
All commands are preceded by the START condition, which is
a HIGH to LOW transition of SDA when SCL is HIGH. The
device continuously monitors the SDA and SCL lines for the
START condition and does not respond to any command until
this condition has been met. On power up, the SCL pin must
be brought LOW prior to the START condition.
Serial STOP Condition
All communications must be terminated by a STOP condition,
which is a LOW to HIGH transition of SDA when SCL is HIGH
followed by a HIGH to LOW on SCL. After going LOW, SCL
can stay LOW or return to HIGH. The STOP condition also
places the device into the Standby power mode after a read
sequence.
Serial Acknowledge
Acknowledge is a software convention used to indicate
successful data transfer. The transmitting device, either master
or slave, releases the bus after transmitting eight bits. During
the ninth clock cycle, the receiver pulls the SDA line LOW to
acknowledge that it received the eight bits of data. See Figure
12.
The device responds with an acknowledge after recognition of
a START condition and if the correct Device Identifier and
Select bits are contained in the Slave Address Byte. If a write
operation is selected, the device responds with an
acknowledge after the receipt of each subsequent eight bit
word. The device acknowledges all incoming data and address
bytes, except for the Slave Address Byte when the Device
Identifier and/or Select bits are incorrect.
The device does not acknowledge any instructions following a
non-volatile write operation, unless the VP pin has the
recommended programming voltage applied for the duration of
the write cycle.
In the read mode, the device transmits eight bits of data,
releases the SDA line, then monitors the line for an
acknowledge. If an acknowledge is detected and no STOP
condition is generated by the master, the device continues
transmitting data. The device terminates further data trans-
missions if an acknowledge is not detected. The master must
then issue a STOP condition to return the device to Standby
mode and place the device into a known state.
Device Addressing
Addressing Protocol Overview
Depending upon the operation to be performed on each of
these individual parts, a 1, 2 or 3 Byte protocol is used. All
operations however must begin with the Slave Address Byte
being clocked into the SMBus port on the SCL and SDA pins.
The Slave address selects the part of the device to be
addressed, and specifies if a Read or Write operation is to be
performed.
Slave Address Byte
Following a START condition, the master must output a Slave
Address Byte. This byte consists of three parts:
• The Device Type Identifier which consists of the most
significant four bits of the Slave Address (SA7 - SA4).
SCL
SDA
Start
Stop
FIGURE 11. VALID START AND STOP CONDITIONS
Data Output from
Transmitter
Data Output from
Receiver
8
1
9
Start
Acknowledge
SCL from
Master
FIGURE 12. ACKNOWLEDGE RESPONSE FROM RECEIVER



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com