14 / 18 page ![]() X80140, X80141, X80142, X80143, X80144 FN8153 Rev 0.00 Page 14 of 18 January 20, 2005 Bus Interface Information Interface Conventions The device supports a bidirectional bus oriented protocol. The protocol defines any device that sends data onto the bus as a transmitter, and the receiving device as the receiver. The device controlling the transfer is called the master and the device being controlled is called the slave. The master always initiates data transfers, and provides the clock for both transmit and receive operations. Therefore, the devices in this family operate as slaves in all applications. It should be noted that the ninth clock cycle of the read operation is not a “don’t care.” To terminate a read operation, the master must either issue a STOP condition during the ninth cycle or hold SDA HIGH during the ninth clock cycle and then issue a STOP condition. Serial Clock and Data Data states on the SDA line can change only during SCL LOW. SDA state changes during SCL HIGH are reserved for indicating START and STOP conditions. See Figure 11. Serial START Condition All commands are preceded by the START condition, which is a HIGH to LOW transition of SDA when SCL is HIGH. The device continuously monitors the SDA and SCL lines for the START condition and does not respond to any command until this condition has been met. On power up, the SCL pin must be brought LOW prior to the START condition. Serial STOP Condition All communications must be terminated by a STOP condition, which is a LOW to HIGH transition of SDA when SCL is HIGH followed by a HIGH to LOW on SCL. After going LOW, SCL can stay LOW or return to HIGH. The STOP condition also places the device into the Standby power mode after a read sequence. Serial Acknowledge Acknowledge is a software convention used to indicate successful data transfer. The transmitting device, either master or slave, releases the bus after transmitting eight bits. During the ninth clock cycle, the receiver pulls the SDA line LOW to acknowledge that it received the eight bits of data. See Figure 12. The device responds with an acknowledge after recognition of a START condition and if the correct Device Identifier and Select bits are contained in the Slave Address Byte. If a write operation is selected, the device responds with an acknowledge after the receipt of each subsequent eight bit word. The device acknowledges all incoming data and address bytes, except for the Slave Address Byte when the Device Identifier and/or Select bits are incorrect. The device does not acknowledge any instructions following a non-volatile write operation, unless the VP pin has the recommended programming voltage applied for the duration of the write cycle. In the read mode, the device transmits eight bits of data, releases the SDA line, then monitors the line for an acknowledge. If an acknowledge is detected and no STOP condition is generated by the master, the device continues transmitting data. The device terminates further data trans- missions if an acknowledge is not detected. The master must then issue a STOP condition to return the device to Standby mode and place the device into a known state. Device Addressing Addressing Protocol Overview Depending upon the operation to be performed on each of these individual parts, a 1, 2 or 3 Byte protocol is used. All operations however must begin with the Slave Address Byte being clocked into the SMBus port on the SCL and SDA pins. The Slave address selects the part of the device to be addressed, and specifies if a Read or Write operation is to be performed. Slave Address Byte Following a START condition, the master must output a Slave Address Byte. This byte consists of three parts: • The Device Type Identifier which consists of the most significant four bits of the Slave Address (SA7 - SA4). SCL SDA Start Stop FIGURE 11. VALID START AND STOP CONDITIONS Data Output from Transmitter Data Output from Receiver 8 1 9 Start Acknowledge SCL from Master FIGURE 12. ACKNOWLEDGE RESPONSE FROM RECEIVER |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |