Electronic Components Datasheet Search
  English  ▼

X  

TC237B Datasheet(PDF) 3 Page - Texas Instruments

Part # TC237B
Description  680-횞500-PIXEL CCD IMAGE SENSOR
PDF  15 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  TI [Texas Instruments]
Direct Link  http://www.ti.com
Logo TI - Texas Instruments

TC237B Datasheet(HTML) 3 Page - Texas Instruments

  TC237B Datasheet HTML 1Page - Texas Instruments TC237B Datasheet HTML 2Page - Texas Instruments TC237B Datasheet HTML 3Page - Texas Instruments TC237B Datasheet HTML 4Page - Texas Instruments TC237B Datasheet HTML 5Page - Texas Instruments TC237B Datasheet HTML 6Page - Texas Instruments TC237B Datasheet HTML 7Page - Texas Instruments TC237B Datasheet HTML 8Page - Texas Instruments TC237B Datasheet HTML 9Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 3 / 15 page
background image
TC237B
680-
× 500-PIXEL CCD IMAGE SENSOR
SOCS063 – APRIL 2001
3
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
Terminal Functions
TERMINAL
I/O
DESCRIPTION
NAME
NO.
I/O
DESCRIPTION
ADB
4
I
Supply voltage for amplifier drain bias
IAG1
12
I
Image area gate 1
IAG2
2
I
Image area gate 2
ODB
1
I
Supply voltage for drain antiblooming bias
OUT1
5
O
Output signal 1
OUT2
6
O
Output signal 2
RST
7
I
Reset gate
SAG
10, 11
I
Storage area gate
SRG
8
I
Serial register gate
SUB
3, 9
Substrate
detailed description
The TC237B CCD image sensor consists of four basic functional blocks: the image-sensing area, the image
storage area, the serial register gates, and the low-noise signal processing amplifier block with charge detection
nodes and independent resets. The location of each of these blocks is identified in the functional block diagram.
image-sensing and image storage areas
Figure 1 and Figure 2 show cross sections with potential well diagrams and top views of the image-sensing and
storage area elements. As light enters the silicon in the image-sensing area, electrons are generated and
collected in the wells of the sensing elements. Blooming protection is provided by applying a dc bias to the
overflow drain bias pin. To clear the image before beginning a new integration time (for implementation of
electronic fixed shutter or electronic auto-iris), apply a pulse of at least 1
µs to the overflow drain bias. After
integration is complete, charge voltage is transferred into the storage area. The transfer timing depends on
whether the readout mode is interlace or progressive scan. If the progressive-scan readout mode is selected,
the readout may be performed by using one serial register or at high speed by using both serial registers (see
Figure 3 through Figure 5). A line-summing operation, which is useful in off-chip smear subtraction, can be
implemented before the parallel transfer (see Figure 6).
Twenty-two columns at the left edge of the image-sensing area are shielded from incident light; these elements
provide the dark reference used in subsequent video-processing circuits to restore the video black level. In
addition, four dark lines between the image-sensing and the image storage area prevent charge leakage from
the image-sensing area into the image storage area.
advanced lateral overflow drain
The advanced lateral overflow drain structure is shared by two neighboring pixels and provides several unique
features in the sensor. By varying the dc bias of the drain pin, you can control the blooming protection level and
trade it for the well capacity.
To clear charge voltages in the image area, apply a 10-V pulse for a minimum duration of 1
µs above the nominal
dc bias level. This feature permits a precise control of the integration time on a frame-by-frame basis. The
single-pulse clear capability also reduces smear by eliminating accumulated charge from the pixels before the
start of the integration (single-sided smear).
Application of a negative 1-V pulse to the ODB signal during the parallel transfer is recommended to prevent
slight column-to-column pixel well capacity variations in some artifacts.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com