| Electronic Components Datasheet Search |
|
CS5464 Datasheet(PDF) 15 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
CS5464 Datasheet(HTML) 15 Page - Cirrus Logic |
|
15 / 46 page ![]() CS5464 DS682PP1 15 from the calculated VRMS and IRMS as well as the appar- ent power. When the optional HPF in either channel is disabled, an all-pass filter (APF) in the complement channel is imple- mented. The APF has an amplitude response that is flat within the channel bandwidth and is used for matching phase in systems where only one channel’s HPF is en- gaged. For more information, see 5.3 High-pass Filters on page 17. 4.2 Voltage and Current Measurements The digital filter output word is subject to a DC offset ad- justment and a gain calibration (See Section 7. System Calibration on page 39). The calibrated measurement is available by reading the instantaneous voltage and cur- rent registers. The Root Mean Square (RMS in Figure 5) calculations are performed on N instantaneous voltage and current samples, Vn and In, respectively (where N is the cycle count), using the formula: and likewise for VRMS, using Vn. IRMS and VRMS are ac- cessible by register reads, which are updated once ev- ery cycle count (referred to as a computational cycle). 4.3 Power Measurements The instantaneous voltage and current samples are multiplied to obtain the instantaneous power (see Fig- ure 3 and 4). The product is then averaged over N con- versions to compute active power and is used to drive energy pulse output E1. Energy output E2 is config- urable and can provide an energy sign, a pulse output that is proportional to the apparent power, or a tamper indicator. Energy output E3 provides a pulse output that is proportional to the reactive power or the apparent power. Output E3 can also be set to indicate the PFMON comparator output or to indicate the sign of the voltage applied to the voltage channel. The apparent power (S, S2) is the combination of the active power and reactive power, without reference to an impedance phase angle, and is calculated by the CS5464 using the following formula: Power Factor (PF, PF2) is the active power (PActive, P2Active) divided by the apparent power (S, S2) The sign of the power factor is determined by the active power. The CS5464 calculates the reactive power (QTrig, Q2Trig) utilizing trigonometric identities, using the formu- la I RMS I n n0 = N1 – ∑ N --------------------- = Iacoff (I2acoff) X V (V2) IRMS (I2RMS) VRMS (V2RMS) I (I2) Energy-to-pulse X + Σ + X + Σ + + Vacoff (V2acoff) Σ + √ N ÷ N Σ N ÷ N Σ PACTIVE (P2ACTIVE) N ÷ N Σ PulseRateE X S (S2) QAVG (Q2AVG) - Σ + X Inverse X PF (PF2) √ QTRIG (Q2TRIG) N ÷ N Σ X √ E3 E2 E1 Poff (P2off) Q (Q2) P (P2) REGISTER NAMES (CHANNEL 2 REGISTER NAMES) INDICATED IN SHADED AREAS. Figure 5. Power Calculation Flow SV RMS I RMS × = PF P Active S ------------------ = Q Trig S2 P Active 2 – = |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |