| Electronic Components Datasheet Search |
|
ADPD7000 Datasheet(PDF) 6 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADPD7000 Datasheet(HTML) 6 Page - Analog Devices |
|
6 / 127 page ![]() Data Sheet ADPD7000 SPECIFICATIONS analog.com Rev. 0 | 6 of 127 Table 2. Performance Specifications (Continued) Parameter Test Condition/Comments Min Typ Max Unit All Functions Enabled (DC Lead Off (DCLO) and AC Lead Off (ACLO) Channel Common-Mode Rejection Ratio (CMRR) Balanced mode, measured at 60 Hz 115 dB Output Date Rate Aligned with filter design 250 4000 Hz ECG Channel Enable Time Data rate of 500 SPS 15 ms Overload Recovery Time 10 ms ECG Channel Power ODR = 500 Hz, ACLO and DCLO functions enabled, resolution = 286 nV/LSB 1.7 mW DCLO DETECTION Drive Circuit Lead Off Current Range Lead fail current is programmable over the specified range, programmed current magnitude setting applies across all electrode pins, current polarity is programmable on individual electrode basis 0 1.1 µA Measure Circuit Right Leg Driver (RLD)2 Lead Off Thresholds AVDD3 − 0.8 AVDD3 − 0.2 V High AVDD3 − 0.8 AVDD3 − 0.2 V Low 0.2 0.8 V ACLO THRESHOLD Drive Circuit Excitation Frequency 4 kHz Current 0 70 nA Measure Circuit Threshold 0.04 2.33 nF RLD Output Voltage GND AVDD3/2 AVDD3 V Stable Load Capacitance 2.2 nF BIA CHANNEL SYSTEM PERFORMANCE For impedance (Z) = 1 kΩ (0.1% tolerant resistor), excitation frequency (fEXCITATION) = 50 kHz, sine amplitude = 0.6 V p-p, TIA resistor (RTIA) = 2 kΩ, TIA capacitor (CTIA) = 7 pF, isolation capacitor = 470 nF, current-limiting resistor (RLIMIT) = 1 kΩ Total System Accuracy Magnitude 0.26 % Phase 1 Degrees Body Impedance Magnitude Error Contact resistor ≤1 kΩ 0.26 % Contact resistor ≤20 kΩ 5 % Body Impedance Magnitude Repeatability Room temperature, test 10 times, contact resistor <1 kΩ 0.1 % Body Phase Angle Error 1 Degrees TRANSMIT STAGE Output Frequency Range 50 250 kHz Output Frequency Resolution 0.48 Hz Output Voltage Range 800 mV Output Voltage Resolution 0.39 mV RECEIVE STAGE Input Leakage Current Input Capacitance Toward ground for current sensing 10 pF Toward ground for voltage sensing 10 pF |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |