| Electronic Components Datasheet Search |
|
UPD17062 Datasheet(PDF) 145 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
UPD17062 Datasheet(HTML) 145 Page - Renesas Technology Corp |
|
145 / 298 page ![]() 143 µPD17062 12.4.2 Correcting the Timer Carry FF at a CE reset This section describes an example of correcting the timer at a CE reset. If the timer carry FF is used both to check for power failure and as a timer, it is necessary to correct the timer at a CE reset, as explained in the following example. The timer carry FF is reset to 0 at a power-on reset, and it is kept from being set until the BTM0CY flag is read-accessed using a PEEK instruction. When the CE pin goes from a low to a high, a CE reset occurs in synchronization with the positive-going edge of the timer carry FF set pulse. At this point, the BTM0CY flag is set to 1 and becomes active. Therefore, checking the state of the BTM0CY flag at a system reset (power-on reset or CE reset) can discriminate between a power-on reset and CE reset; if the flag is 0, it indicates a power-on reset, and if 1, it indicates a CE reset (power failure check). A timer for ordinary time measurement must continue to operate even at a CE-reset. Reading the BTM0CY flag for a power failure check could reset the BTM0CY flag to 0, thus losing a chance of detecting a set (1) state of the flag. To skirt the above problem, it is necessary to update the timer for time measurement at a CE reset that occurs because of power failure. See also Section 14.6 for details about a power failure check. Example Correcting the timer at a CE reset When using the timer carry FF for a power failure check and clock update START: ; Program address 0000H Process A ; # SKT1 BTM0CY ; Built-in macro ; Tests the BTM0CY flag. BR INITIAL ; Branches to INITIAL if 0 (power failure check) BACKUP: ; $ Update the clock by 100 ms ; Correct the clock because of a backup (CE reset). LOOP: ; % Process B ; While performing process B, SKF1 BTM0CY ; tests the BTM0CY flag and updates the clock. BR BACKUP BR LOOP INITIAL: INITFLG NOT BTM0ZX, NOT BTM0CK2, NOT BTM0CK1, NOT BTM0CK0 ; Built-in macro ; Because a power failure (power-on reset) is detected, the timer ; carry FF setting time interval is set to 100 ms, and passes ; control to process C. Process C BR LOOP Fig. 12-6 shows the timing chart for the above program. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |