| Electronic Components Datasheet Search |
|
MAQ430 Datasheet(PDF) 20 Page - MPS Industries, Inc. |
|
|
|||||||||||||||||||||||||||||
MAQ430 Datasheet(HTML) 20 Page - MPS Industries, Inc. |
|
20 / 30 page ![]() MAQ430 – 12-BIT, AUTOMOTIVE ANGLE SENSOR WITH ABZ & UVW OUTPUTS MAQ430 Rev. 1.2 www.MonolithicPower.com 20 8/8/2022 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2022 MPS. All Rights Reserved. The X-axis or the Y-axis bias current can be reduced to recover an equal Hall signal for all angles and suppress the error. The parameter ETX and ETY controls in which direction the sensitivity is reduced. The current reduction is set by the parameter bias current trimming BCT(7:0), which is an integer from 0 to 255. In side-shaft configuration (i.e.: the sensor center is located beyond the magnet outer diameter), k is greater than 1. For optimum compensation, the sensitivity of the radial axis should be reduced by setting the BCT parameter as shown in Equation (6): k BCT 1 1 258 ) 0 : 7 ( (6) Equation (6) is plotted in Figure 17 and Table 11. 0 50 100 150 200 1 1.5 2 2.5 3 3.5 4 4.5 5 k Figure 17: Relation between the k Ratio and the Optimum BCT to Recover Linearity Table 11: Example of BCT Settings E (deg) Magnet Ratio k BCT(7:0) 0 1.0 0 11.5 1.5 86 19.5 2.0 129 25.4 2.5 155 30.0 3.0 172 33.7 3.5 184 36.9 4.0 194 39.5 4.5 201 41.8 5.0 207 Determining k with the MagAlpha It is possible to deduce the k ratio from the error curve obtained with the default BCT setting (BCT = 0). For this purpose, rotate the magnet over one revolution and record the MagAlpha output. Then plot the error curve (the MagAlpha output minus the real mechanical position vs. the real mechanical position) and extract two parameters: the maximum error E and the position of this maximum with respect to a zero crossing am (see Figure 18). k can be calculated with Equation (7): ) tan( ) tan( m m a a E k (7) -40 -20 0 20 40 0 50 100 150 200 250 300 350 m rotor angle (deg) 2E Figure 18: Error Curve in Side-Shaft Configuration with BCT = 0 Some examples are given in Table 11. Alternatively, the k parameter can be obtained from the graph of Figure 19. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |