| Electronic Components Datasheet Search |
|
MAX39 Datasheet(PDF) 8 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
MAX39 Datasheet(HTML) 8 Page - Analog Devices |
|
8 / 29 page ![]() www.analog.com Analog Devices │ 8 MAX30009EVKIT# Evaluation Kit Evaluates: MAX30009 selected by default to use a 47nF capacitor provided by the EV kit to block DC currents from being driven into the patient. When using voltage mode or H-bridge mode as a stimulus, there must be external series precision resistors connected in the DRVP and DRVN paths, and the pins EL1 and EL4 should be connected to DRVP and DRVN respectively. See the BioZ Configurations subsection in the Detailed Description of Hardware section of this data- sheet for hardware components provided by the EV kit. Voltage Mode Amplitude Voltage Mode Amplitude can adjust current and voltage amplitudes from the Current DAC. There are four settings, 35.4mV, 70.7mV, 177mV, and 354mV. When Voltage is selected for the Current DAC Drive Mode, the Voltage Mode Amplitude sets the voltage RMS amplitude at DRVR. When Current is selected for Current DAC Drive Mode, the Voltage Mode Amplitude, and Current Drive Range Resistor sets the current magnitude and changes the voltage amplitude at DRVR depending on the current drive range resistor used. Note that certain amplitudes are not available for certain stimulus frequencies to align with safety standards. Refer to the MAX30009 IC datasheet under the BioZ Transmit Channel section for recommended settings and safety limits. Amplifier Settings The BioZ drive channel contains various amplifier settings to adjust for different BioZ applications. Amplifier Range sets the output stage option for the voltage drive (1st) and current drive (2nd) amplifiers. Higher amplifier ranges are recommended for higher output current loading, although this will consume more power. Amplifier Bandwidth sets the gain bandwidth of the voltage drive and current drive amplifiers. Higher bandwidth is recommended for high- frequency applications including bioimpedance analysis and impedance cardiography. Low bandwidth is recom- mended for low-frequency applications including galvanic skin response to reduce power consumption. Refer to the MAX30009 datasheet under the BioZ Transmit Channel section for more details. Current Drive Range Resistor The BioZ drive channel allows for custom current mag- nitudes to be defined through an internal range resistor. The Current Drive Range Resistor sets the value of this resistor. There are four resistor settings, 552.5kΩ, 100.5kΩ, 5.525kΩ, and 276.25Ω. When Current is select- ed for Current DAC Drive Mode, the Voltage Mode Amplitude and Current Drive Range Resistor sets the current magnitude. Refer to the MAX30009 datasheet under the BioZ Transmit Channel section for more details. External Resistor The BioZ drive channel allows for custom current mag- nitudes to also be defined through an external resistor in place of the internal range resistors. Selecting Use External Resistor selects the external resistor inserted between DRVXR and DRVXC pins to be used in place of the internal range resistors. In this case, Current Drive Range Resistor is ignored. R13 on the EV kit is the exter- nal resistor in a standard 0402 SMT package size. This resistor is not populated on the EV kit to allow the user to populate their own external resistor value. When this option is selected, the resistor value should be entered (in Ω) and the Set button should be pressed. This will calcu- late and display the RMS drive current under the Current Drive Range Resistor pull-down box. External Capacitor When sine wave current is used for stimulation, an exter- nal capacitor must be inserted between DRVXC and DRVSJ to couple AC stimulus current and prevent DC from passing into the patient. Deselecting Use External Capacitor bypasses this external capacitor. DC Restore The BioZ drive channel contains a 10MΩ feedback resis- tance to the current drive amplifier to maintain DC bias of the drive electrodes during a lead-off event and reduce amplifier settling time when the lead is reconnected. Enabling DC Restore applies this feedback resistance, and is required when AC-coupling capacitors are included in the stimulus path (E1_C and/or E4_C jumpers are open). Current DAC Frequency Selection The BioZ drive frequency is generated by dividing the output of the PLL by K Divider and DAC OSR. Changing these fields also changes their values in the PLL tab. Advanced Settings: Enable Drive Out of Range (OOR) Detection This checkbox is identical to the DRVN Out of Range Enable checkbox on the BioZ Mux tab. See the descrip- tion in the BioZ Mux tab section of this document. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |