151 / 227 page ![]() www.ti.com TMS320C6421 Fixed-Point Digital Signal Processor SPRS346B – JANUARY 2007 – REVISED APRIL 2007 Table 6-15. PLLC1 Clock Frequency Ranges CLOCK SIGNAL NAME MIN MAX UNIT MXI/CLKIN(1) 15 30 MHz At 1.2-V CVDD 400 600 MHz PLLOUT At 1.05-V CVDD 400 520 MHz -600 devices 600 MHz SYSCLK1 (CLKDIV1 Domain) -500 devices 500 MHz -400 devices 400 MHz (1) MXI/CLKIN input clock is used for both PLL Controllers (PLLC1 and PLLC2). Table 6-16. PLLC2 Clock Frequency Ranges CLOCK SIGNAL NAME MIN MAX UNIT MXI/CLKIN(1) 15 30 MHz At 1.2-V CVDD 400 900 MHz PLLOUT At 1.05-V CVDD 400 666 MHz PLL2_SYSCLK1 (to DDR2 PHY) 333 MHz (1) MXI/CLKIN input clock is used for both PLL Controllers (PLLC1 and PLLC2). Both PLL1 and PLL2 have stabilization, lock, and reset timing requirements that must be followed. The PLL stabilization time is the amount of time that must be allotted for the internal PLL regulators to become stable after the PLL is powered up (after PLLCTL.PLLPWRDN bit goes through a 1-to-0 transition). The PLL should not be operated until this stabilization time has expired. This stabilization step must be applied after these resets—a Power-on Reset, a Warm Reset, or a Max Reset, as the PLLCTL.PLLPWRDN bit resets to a "1". For the PLL stabilization time value, see Table 6-17. The PLL reset time is the amount of wait time needed for the PLL to properly reset (writing PLLRST = 0) before bringing the PLL out of reset (writing PLLRST = 1). For the PLL reset time value, see Table 6-17. The PLL lock time is the amount of time needed from when the PLL is taken out of reset (PLLRST = 1 with PLLEN = 0) to when to when the PLL controller can be switched to PLL mode (PLLEN = 1). For the PLL lock time value, see Table 6-17. Table 6-17. PLL1 and PLL2 Stabilization, Lock, and Reset Times PLL STABILIZATION/LOCK/RESET MIN TYP MAX UNIT TIME PLL Stabilization Time 150 µs PLL Lock Time 2000C(1) ns PLL Reset Time 128C(1) ns (1) C = CLKIN cycle time in ns. For example, when MXI/CLKIN frequency is 25 MHz, use C = 40 ns. For details on the PLL initialization software sequence, see the TMS320C642x DSP Phase-Locked Loop Controller (PLLC) User's Guide (literature number SPRUES0). For more information on the clock domains and their clock ratio restrictions, see Section 6.3.4, C6421 Power and Clock Domains. Submit Documentation Feedback Peripheral Information and Electrical Specifications 151 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |