6 / 17 page ![]() Type 8232 6 | 17 Visit product website Sensor model Free chlorine sensor “Trace” (zero-chlorine) Free chlorine sensor with 3 electrodes Free chlorine sensor with 2 electrodes Total chlorine sensor with 3 electrodes Output Voltage (4-wire): • Analog signal • 0…2000 mV (max. 2500 mV) • Galvanically insu- lated, that means potential-free • Output resistance: 1 kΩ Current (2-wire): • Analog signal • 4…20 mA (uncalibrat- ed, at pH 7.2 nominal slope 0.8 mA/ppm) • Not galvanically insulated4.) • Max. loop impedance (valid with Type 8619 multiCELL3.)): 50 Ω at 12 V DC, 900 Ω at 30 V DC Current (2-wire): • Analog signal • 4…20 mA (uncalibrat- ed, at pH 7.2 nominal slope 0.8 mA/ppm) • Not galvanically insulated4.) • Max. loop impedance (valid with Type 8619 multiCELL3.)): 50 Ω at 12 V DC, 900 Ω at 30 V DC Current (2-wire): • Analog signal • 4…20 mA (uncalibrat- ed, at pH 7.2 nominal slope 3.2 mA/ppm for variant 0.05…5 ppm or 0.8 mA/ ppm for variant 0.05…20 ppm) • Not galvanically insulated4.) • Max. loop impedance (valid with Type 8619 multiCELL-): 50 Ω at 12 V DC, 900 Ω at 30 V DC Medium data Fluid Water with similar char- acteristics to drinking water • Drinking water, swim- ming pool water, sea water • Surfactants are par- tially tolerated • Swimming pool water, drinking water, service water, pro- cess water • Free of any sur- factants • With constant pH value • Drinking water, swim- ming pool water, sea water, brine (15 % NaCl) • Surfactants are par- tially tolerated Fluid flow rate 15…30 l/h mounted in analytical measure- ment chamber 8200, the measuring value depends on the flow rate (ensure constant flow rate) 15…30 l/h mounted in analytical measure- ment chamber 8200, the measuring value depends on the flow rate (ensure constant flow rate) Detailed information can be found in chapter “Slope versus flow rate” on page 11. 15…30 l/h mounted in analytical measure- ment chamber 8200, the measuring value depends on the flow rate (ensure constant flow rate) Detailed information can be found in chapter “Slope versus flow rate” on page 12. 15…30 l/h mounted in analytical measure- ment chamber 8200, the measuring value depends on the flow rate (ensure constant flow rate) Detailed information can be found in chapter “Slope versus flow rate” on page 13. Fluid pH range pH 6.5…pH 9 Detailed information can be found in chapter “Slope versus pH” on page 10. pH 4…pH 9 Detailed information can be found in chapter “Slope versus pH” on page 11. pH 6…pH 8 (attention to the dissociation equili- brum HOCl, pH has to be constant) Detailed information can be found in chapter “Slope versus pH” on page 12. pH 4…pH 12, reduced dependence on pH value Detailed information can be found in chapter “Slope versus pH” on page 13. Fluid conductivity – 10 μS/cm…50 mS/cm (sea water) – 10 μS/cm…200 mS/cm (brine water) Fluid temperature 0…+ 40 °C (+ 32…+ 104 °F) 0…+ 45 °C (+ 32…+ 113 °F) 0…+ 45 °C (+ 32…+ 113 °F) 0…+ 45 °C (+ 32…+ 113 °F) No ice crystals in the measuring water. If the temperature ranges given for the holder and the used sensor are different, use the most restrictive range. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |