Back Button 2852 Datasheet HTML 2Page - Christian Bürkert GmbH & Co. KG 2852 Datasheet HTML 3Page - Christian Bürkert GmbH & Co. KG 2852 Datasheet HTML 4Page - Christian Bürkert GmbH & Co. KG 2852 Datasheet HTML 5Page - Christian Bürkert GmbH & Co. KG 2852 Datasheet HTML 6Page - Christian Bürkert GmbH & Co. KG 2852 Datasheet HTML 7Page - Christian Bürkert GmbH & Co. KG 2852 Datasheet HTML 8Page - Christian Bürkert GmbH & Co. KG 2852 Datasheet HTML 9Page - Christian Bürkert GmbH & Co. KG 2852 Datasheet HTML 10Page - Christian Bürkert GmbH & Co. KG  
Zoom Inzoom in Zoom Outzoom out
 7 / 10 page
background image
Type 2852
7 | 10
Visit product website 
6.
Performance specifications
6.1. Flow characteristic
Note:
The design of the nominal size of proportional valves is very important for the correct functioning within the application. The nominal size
must be selected so that, on the one hand, the desired flow range is achieved and that, on the other hand, a sufficient part of the total
pressure drop occurs via the valve when the valve is fully open. This means that the flow range in the controlled system is completely
determined by the proportional valve.
The flow characteristics shown below have been recorded without back pressure and are purely exemplary. The flow characteristics may
vary due to specific installation situations and operating conditions.
The valve Type 2852 is suitable for applications with back pressure. With a high inlet pressure in conjunction with a high back pressure, it
should be noted that the flow characteristic curve has an increasingly high gradient in some areas and that discontinuities may occur. High
thermal load combined with high inlet pressure may have an impact on the flow characteristic in the lower flow range. This can have a
negative effect on the control behaviour.
For further information and support with the design, please contact your local Bürkert partner.
Flow characteristics as a function of the coil current
0
50
100
150
200
250
300
350
40
60
80
100
120
140
I [mA]
1 bar
2.5 bar
5 bar
7 bar
Maximum flow rate as a function of the operating pressure
0
50
100
150
200
250
300
350
0
1
2
3
4
5
6
7
P [bar
g]



Html Pages

1 2 3 4 5 6 7 8 9 10


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com