18 / 35 page

- 18 -
© Andigilog, Inc. 2006
www.andigilog.com
August 2006 - 70A05003
aSC7512
Bit
Name
R/W
Default
Description
1:0
Measurement
Duration
R/W
10
The amount of fan rotation used for the tach measurement.
Assumes 2 pulse periods per rotation of fan.
00: ¼ Rotation – Tach Count x4 = Reported Value
01: ½ Rotation – Tach Count x2 = Reported Value
10: 1 Rotation – Tach Count x1 = Reported Value (default)
11: 2 Rotation – Tach Count x1 = Reported Value
3:2
Measurement
Dwell
R/W
01
Delay between Tach Measurements
00: 100 ms
01: 300 ms (default)
10: 500 ms
11: 728 ms
5:4
Measurement
Blank
R/W
11
In 3-wire fan mode, a delay is needed to assure that the
tach input has stabilized after the PWM has been set to
100%
00: 11.1 µs
01: 22.2 µs
10: 33.3 µs
11: 44.4 µs (default)
6
3-Wire
Enable
R/W
0
When high, forces the PWM to stay high for the duration of
a tach measurement for a 3-wire fan. This will result in
increasing the PWM on-time percentage vs. the value in
the PWM register.
7
Tach Disable
R/W
0
Suspends the 90KHz clock for power savings when high.
Table 8 Tachometer Configuration Register