10 / 12 page ![]() 10 LT1249 APPLICATIONS INFORMATION voltages above 8V and the 12V limit is only for surge conditions. In normal operation, the voltage into MOUT does not exceed 1.1V, but under surge conditions, the voltage could temporarily go higher. To date, no field failures due to surges have been reported for normal LT1249 configu- rations, but if the possibility exists for extremely large current surges, please read the following discussion. Offline switching power supplies can create large current surges because of the high value storage capacitor used. The surge can be the result of closing the line switch near the peak of the AC line voltage, or because of a large transient in the line itself. These surges are well known in the power supply business, and are normally controlled with a negative temperature coefficient thermistor in series with the rectifier bridge. When power is switched on, the thermistor is cold (high resistance) and surges are limited. Current flow in the thermistor causes it to heat and resistance drops to the point where overall efficiency loss in the resistor is acceptable. This basic protection mechanism can be partially defeated if the power supply is switched off for a few seconds, then turned back on. The thermistor has not had time to cool significantly and if the subsequent turn-on catches the AC line near its peak, the resulting surge is much higher than normal. Even if this surge current generates a voltage greater than 6V (but less than 12V) across the sense resistor, the standard LT1249 application will not be affected because the chip is not yet powered. Problems are only created if the VCC pin is powered from some external housekeeping supply that remains powered when bridge power is switched off. A huge line voltage surge, beyond the normal worst-case limits, can also create a large current surge. The peak of the line voltage must significantly exceed the storage capacitor voltage (typically 380V) for this to occur, so peak line voltage would probably have to exceed 450V. Such excessive surges might occur if a very large mains load was suddenly removed, with a resulting line “kickback”. If the surge results in voltage at the MOUT pin greater than 6V, it must also last more than 30 µs (three switch cycles) to cause FET problems. External Clamp The external clamp shown in Figure 6 will protect the LT1249 MOUT pin against extremely large line current surges (see above). Protection is provided for all VCC power methods. The 100 Ω resistor and three diodes limit the peak negative voltage into MOUT to less than 3V. Current sense gain is attenuated by only 100 Ω/4000Ω = 2.5%. Three diodes are used because the peak negative voltage into MOUT in normal operation could go as high as –1.1V and the diodes should not conduct more than a few microamps under this condition. Figure 6. Protecting MOUT from Extremely High Current Surges THERMISTOR 100 Ω RS SURGE PATH STORAGE CAPACITOR MOUT LT1249 + – BRIDGE + |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |