| Electronic Components Datasheet Search |
|
LTC2489CDEPBF Datasheet(PDF) 10 Page - Linear Technology |
|
|
|||||||||||||||||||||||||||||
LTC2489CDEPBF Datasheet(HTML) 10 Page - Linear Technology |
|
10 / 24 page ![]() LTC2489 10 2489f cancellation does not interfere with the transparent offset and full-scale auto-calibration and the absolute accuracy (full scale + offset + linearity + drift) is maintained even with external RC networks. Power-Up Sequence The LTC2489 automatically enters an internal reset state when the power supply voltage, VCC, drops below ap- proximately 2.0V. This feature guarantees the integrity of the conversion result and input channel selection. When VCC rises above this threshold, the converter creates an internal power-on-reset (POR) signal with a duration of approximately 4ms. The POR signal clears all internal registers. The conversion immediately following a POR cycle is performed on the input channels IN+ = CH0 and IN– = CH1. The first conversion following a POR cycle is accurate within the specification of the device if the power supply voltage is restored to (2.7V to 5.5V) before the end of the POR interval. A new input channel can be programmed into the device during this first data input/ output cycle. Reference Voltage Range This converter accepts a truly differential, external refer- ence voltage. The absolute/common mode voltage range for the REF+ and REF– pins covers the entire operating range of the device (GND to VCC). For correct converter operation, VREF must be positive (REF+ > REF–). The LTC2489 differential reference input range is 0.1V to VCC. For the simplest operation, REF+ can be shorted to VCC and REF– can be shorted to GND. The converter output noise is determined by the thermal noise of the front end circuits. Since the transition noise is well below 1LSB (0.02LSB), a decrease in reference voltage will proportionally improve the converter resolution and improve INL. Input Voltage Range The analog inputs are truly differential with an absolute, common mode range for the CH0-CH3 and COM input pins extending from GND – 0.3V to VCC + 0.3V. Within these limits, the LTC2489 converts the bipolar differen- tial input signal VIN = IN+ – IN– (where IN+ and IN– are the selected input channels), from –FS = –0.5 • VREF to +FS = 0.5 • VREF where VREF = REF+ - REF–. Outside this range, the converter indicates the overrange or the underrange condition using distinct output codes (see Table 1). In order to limit any fault current due to input ESD leakage current, resistors of up to 5k may be added in series with the input. The effect of series resistance on the converter accuracy can be evaluated from the curves presented in the Input Current/Reference Current sections. In addition, series resistors will introduce a temperature dependent error due to input leakage current. A 1nA input leakage current will develop a 1ppm offset error on a 5k resistor if VREF = 5V. This error has a very strong temperature dependency. I2C INTERFACE The LTC2489 communicates through an I2C interface. The I2C interface is a 2-wire open-drain interface supporting multiple devices and multiple masters on a single bus. The connected devices can only pull the data line (SDA) low and can never drive it high. SDA is required to be externally connected to the supply through a pull-up resistor. When the data line is not being driven, it is high. Data on the I2C bus can be transferred at rates up to 100kbits/s in the standard mode and up to 400kbits/s in the fast mode. Each device on the I2C bus is recognized by a unique address stored in that device and can operate either as a transmitter or receiver, depending on the function of the device. In addition to transmitters and receivers, devices can also be considered as masters or slaves when perform- ing data transfers. A master is the device which initiates a data transfer on the bus and generates the clock signals to permit that transfer. Devices addressed by the master are considered a slave. The LTC2489 can only be addressed as a slave. Once ad- dressed, it can receive channel selection bits or transmit the last conversion result. The serial clock line, SCL, is always an input to the LTC2489 and the serial data line SDA is bidirectional. The device supports the standard mode and the fast mode for data transfer speeds up to 400kbits/s. Figure 2 shows the definition of the I2C timing. APPLICATIONS INFORMATION |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |