10 / 22 page ![]() 1.0 Functional Description (Continued) Register flags are updated at the completion of a conversion, which occurs approximately 60 ms after a temperature diode is sampled. INT is deactivated when the Status Register, containing the set bit, is read and a temperature reading is less than or equal to it’s corresponding HIGH setpoint, as shown in Figure 4. Figure 5shows a simplified logic diagram for the INT output and related circuitry. The INT output can be disabled by setting the INT mask bit, D7, of the configuration register. INT can be programmed to be active high or low by the state of the INT inversion bit, D1, in the configuration register. A “0” would program INT to be active low. INT is an open-drain output. 1.3 T_CRIT_A OUTPUT and T_CRIT LIMIT T_CRIT_A is activated when any temperature reading is greater than the limit preset in the critical temperature set- point register (T_CRIT), as shown in Figure 6. The Status Registers can be read to determine which event caused the alarm. A bit in the Status Registers is set high to indicate which temperature reading exceeded the T_CRIT setpoint temperature and caused the alarm, see Section 2.3. Local and remote temperature diodes are sampled in se- quence by the A/D converter. The T_CRIT_A output and the Status Register flags are updated at the completion of a con- version. T_CRIT_A and the Status Register flags are reset only after the Status Register is read and if a temperature conversion is below the T_CRIT setpoint, as shown in Figure 6. Figure 7 shows a simplified logic diagram of the T_CRIT_A and related circuitry. Located in the Configuration Register are the mask bits for each temperature reading, see Section 2.5. When a mask bit is set, its corresponding status flag will not propagate to the T_CRIT_A output, but will still be set in the Status Registers. Setting all four mask bits or programming the T_CRIT set- point to 127˚C will disable the T_CRIT_A output. 1.4 POWER ON RESET DEFAULT STATES LM83 always powers up to these known default states: 1. Command Register set to 00h 2. Local Temperature set to 0˚C DS101058-14 * Note: Status Register Bits are reset by a read of Status Register where bit is located. FIGURE 4. INT Temperature Response Diagram with D2RHS and D3RHS set to 127˚C. DS101058-21 FIGURE 5. INT output related circuitry logic diagram DS101058-6 * Note: Status Register Bits are reset by a read of Status Register where bit is located. FIGURE 6. T_CRIT_A Temperature Response Diagram with remote diode 1 and local temperature masked. DS101058-20 FIGURE 7. T_CRIT_A output related circuitry logic diagram www.national.com 9 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |