Back Button LMK02002 Datasheet HTML 10Page - Texas Instruments LMK02002 Datasheet HTML 11Page - Texas Instruments LMK02002 Datasheet HTML 12Page - Texas Instruments LMK02002 Datasheet HTML 13Page - Texas Instruments LMK02002 Datasheet HTML 14Page - Texas Instruments LMK02002 Datasheet HTML 15Page - Texas Instruments LMK02002 Datasheet HTML 16Page - Texas Instruments LMK02002 Datasheet HTML 17Page - Texas Instruments LMK02002 Datasheet HTML 18Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 14 / 24 page
background image
LMK02002
SNAS418 – AUGUST 2007
www.ti.com
EN_CLKout_Global bit
Clock Outputs
0
All Off
1
Normal Operation (default)
PLL_CP_TRI bit -- PLL Charge Pump TRI-STATE
This bit sets the PLL charge pump TRI-STATE.
PLL_CP_TRI
PLL Charge Pump
0
Normal operation (default)
1
TRI-STATE
PLL_CP_POL bit -- PLL Charge Pump Polarity
This bit sets the polarity of the charge pump to either negative or positive. A negative charge pump is used with a
VCO or VCXO which decreases frequency with increasing tuning voltage. A positive charge pump is used with a
VCO or VCXO which increases frequency with increasing tuning voltage.
PLL_CP_POL
PLL Charge Pump Polarity
0
Negative (default)
1
Positive
Register R15
PLL_N[17:0] -- PLL N Divider
These bits program the divide value for the PLL N Divider. The PLL N Divider follows the VCO Divider and
precedes the PLL phase detector. Since the VCO Divider is also in the feedback path from the VCO to the PLL
Phase Detector, the total N divide value, NTotal, is also influenced by the VCO Divider value. NTotal = PLL N
Divider × VCO Divider. The VCO frequency is calculated as, fVCO = fOSCin × PLL N Divider × VCO Divider / PLL R
Divider. Since the PLL N divider is a pure binary counter, there are no illegal divide values for PLL_N[17:0]
except for 0.
PLL_N[17:0]
PLL N Divider Value
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Invalid
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
...
0
0
0
0
0
0
0
0
1
0
1
1
1
1
1
0
0
0
760 (default)
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
...
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
262143
PLL_CP_GAIN[1:0] -- PLL Charge Pump Gain
These bits set the charge pump gain of the PLL.
PLL_CP_GAIN[1:0]
Charge Pump Gain
0
1x (default)
1
4x
2
16x
3
32x
14
Submit Documentation Feedback
Copyright © 2007, Texas Instruments Incorporated
Product Folder Links: LMK02002



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com