Back Button OPA698 Datasheet HTML 25Page - Texas Instruments OPA698 Datasheet HTML 26Page - Texas Instruments OPA698 Datasheet HTML 27Page - Texas Instruments OPA698 Datasheet HTML 28Page - Texas Instruments OPA698 Datasheet HTML 29Page - Texas Instruments OPA698 Datasheet HTML 30Page - Texas Instruments OPA698 Datasheet HTML 31Page - Texas Instruments OPA698 Datasheet HTML 32Page - Texas Instruments OPA698 Datasheet HTML 33Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 29 / 34 page
background image
www.ti.com
R
F
1k
Ω
±200mV Output Adjustment
= -
= -2
Supply Decoupling
Not Shown
5k
Ω
5k
Ω
328
Ω
0.1
µF
R
G
500
Ω
V
I
20k
Ω
10k
Ω
0.1
µF
-5V
+5V
OPA698
+5V
-5V
V
O
V
O
V
I
R
F
R
G
S0050-01
Board Layout Guidelines
OPA698M
SGLS287A – MAY 2005 – REVISED MARCH 2006
Figure 71. DC-Coupled, Inverting Gain of -2, With Offset Adjustment
Achieving optimum performance with the high-frequency OPA698 requires careful attention to layout design and
component selection. Recommended PCB layout techniques and component selection criteria are:
1. Minimize parasitic capacitance to any ac ground for all of the signal I/O pins. Open a window in the ground and
power planes around the signal I/O pins and leave the ground and power planes unbroken elsewhere.
2. Provide a high quality power supply. Use linear regulators, ground plane and power planes to provide power. Place
high frequency 0.1-µF decoupling capacitors < 0.2" away from each power-supply pin. Use wide, short traces to connect
to these capacitors to the ground and power planes. Also use larger (2.2 µF to 6.8 µF) high-frequency decoupling
capacitors to bypass lower frequencies. They may be somewhat further from the device, and be shared among several
adjacent devices.
3. Place external components close to the OPA698. This minimizes inductance, ground loops, transmission line effects
and propagation delay problems. Be extra careful with the feedback (RF), input and output resistors.
4. Use high-frequency components to minimize parasitic elements. Resistors should be a low reactance type.
Surface-mount resistors work best and allow a tighter layout. Metal film or carbon composition axially-leaded resistors
can also provide good performance when their leads are as short as possible. Never use wire-wound resistors for
high-frequency applications. Remember that most potentiometers have large parasitic capacitances and inductances.
Multilayer ceramic chip capacitors work best and take up little space. Monolithic ceramic capacitors also work well. Use
RF type capacitors with low ESR and ESL. The large power pin bypass capacitors (2.2 µF to 6.8 µF) should be tantalum
for better high frequency and pulse performance.
5. Choose low resistor values to minimize the time constant set by the resistor and its parasitic parallel capacitance.
Good metal film or surface mount resistors have approximately 0.2-pF parasitic parallel capacitance. For resistors
> 1.5 k
Ω, this adds a pole and/or zero below 500 MHz. Make sure that the output loading is not too heavy. The
recommended 402-
Ω feedback resistor is a good starting point in most designs.
6. Use short direct traces to other wideband devices on the board. Short traces act as a lumped capacitive load. Wide
traces (50 to 100 mils) should be used. Estimate the total capacitive load at the output, and use the series isolation
resistor recommended in the typical performance curve, RS vs Capacitive Load. Parasitic loads < 2 pF may not need the
isolation resistor.
7. When long traces are necessary, use transmission line design techniques (consult an ECL design handbook for
microstrip and stripline layout techniques). A 50-
Ω transmission line is not required on board—higher characteristic
impedance helps reduce output loading. Use a matching series resistor at the output of the op amp to drive a
transmission line and a matched load resistor at the other end to make the line appear as a resistor. If the 6 dB of
attenuation that the matched load produces is not acceptable and the line is not too long, use the series resistor at the
source only. This isolates the source from the reactive load presented by the line, but the frequency response is
degraded. Multiple destination devices are best handled as separate transmission lines, each with its own series source
and shunt load terminations. Any parasitic impedances acting on the terminating resistors alters the transmission line
match and can cause unwanted signal reflections and reactive loading.
8. Do not use sockets for high-speed parts like the OPA698. The additional lead length and pin-to-pin capacitance
introduced by the socket creates an extremely troublesome parasitic network. Best results are obtained by soldering the
part onto the board.
29
Submit Documentation Feedback



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com