| Electronic Components Datasheet Search |
|
SIC1182K Datasheet(PDF) 4 Page - Power Integrations, Inc. |
|
|
|||||||||||||||||||||||||||||
SIC1182K Datasheet(HTML) 4 Page - Power Integrations, Inc. |
|
4 / 16 page ![]() Rev. D 09/19 4 SIC1182K www.power.com Safe Power-Up and Power-Down It is recommended during power-up and power-down that the IN pin stays at logic low. Any supply voltage related to VCC, VISO, VEE and VGXX pins should be stabilized using ceramic capacitors C 1, C2, C S1, CS2, and CGXX respectively as shown in Figure 5, 6, 7 and 8. After supply voltages reach their nominal values, the driver will begin to function after a time delay t START. Short-Pulse Operation If command signals applied to IN are shorter than the minimum specified by t GE(MIN), then SIC1182K output signals at GH and GL will extend to a value of t GE(MIN). The duration of pulses longer than tGE(MIN) will not be changed. Short-Circuit Protection The SIC1182K uses the semiconductor device drain to source voltage to detect a short-circuit utilizing a sensing resistor network. With the help of a well stabilized V VISO and a Schottky diode connected between semiconductor device gate and VISO the VGE is clamped to the regulated VISO and the short-circuit current as well related SiC semiconductor energy will be limited. During the off-state, SNS is internally connected to the COM pin. In case an optional filter-capacitor is applied between SNS pin and COM this capacitor is discharged. When the driver is in turn-on transition or in on-state, the short-circuit detection algorithm through SNS is activated after an ASIC internally blanking time has elapsed. If now a voltage drop of about 0.4 V (typically) is detected at SNS referenced to VEE, this is interpreted as a detected short-circuit. The driver initiates a short- circuit turn-off without receiving a primary-side command. A fault command is sent to the primary side and SO is pulled to GND for typically 10 µs. During this time the driver ignores any command signal at the IN pin. In parallel to the short-circuit turn-off transition phase, the SCALE-iDriver’s internal Advanced Active Clamping over- voltage limitation scheme is activated. V DS Overvoltage Limitation (Advanced Active Clamping) If the driver is in turn-off transition or in off-state the overvoltage limitation algorithm is activated at SNS and the internal reference is COM. In case a current of typically 440 µA (turn-off transition) to 520 µA (off-state) is feed to SNS, the driver will regulate the gate current to limit the turn-off di/dt and therefore the overvoltage at drain to source during turn-off. Over-Current Detection In case the semiconductor device offers a so called current-sense terminal, this signal can be fed into SNS with reference to VEE. As described in the short-circuit protection section, a voltage of about 0.4 V at SNS with reference to VEE will now be handled as an over-current. That leads to an over-current turn-off, following the same scheme as for a short-circuit condition. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |