| Electronic Components Datasheet Search |
|
DLP9000 Datasheet(PDF) 13 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
DLP9000 Datasheet(HTML) 13 Page - Texas Instruments |
|
13 / 58 page ![]() 13 DLP9000 www.ti.com DLPS036B – SEPTEMBER 2014 – REVISED OCTOBER 2016 Product Folder Links: DLP9000 Submit Documentation Feedback Copyright © 2014–2016, Texas Instruments Incorporated Recommended Operating Conditions (continued) over operating free-air temperature range (unless otherwise noted) MIN NOM MAX UNIT (11) The DLP9000X, coupled with the DLPC910, is designed for operation at 2 specific DCLK frequencies only - 400 MHz or 480 MHz. 480 MHz operation is only allowed at the specific environmental operating conditions as shown in this table. (12) Refer to Figure 2, Figure 3, and Figure 4. (13) Optimal, long-term performance and optical efficiency of the Digital Micromirror Device (DMD) can be affected by various application parameters, including illumination spectrum, illumination power density, micromirror landed duty-cycle, ambient temperature (storage and operating), DMD temperature, ambient humidity (storage and operating), and power on or off duty cycle. TI recommends that application-specific effects be considered as early as possible in the design cycle. (14) The array temperature cannot be measured directly and must be computed analytically from the temperature measured at test point 1 (TP1) shown in Figure 15 and the package thermal resistance in Thermal Information using Micromirror Array Temperature Calculation. (15) Simultaneous exposure of the DMD to the maximum Recommended Operating Conditions for temperature and UV illumination will reduce device lifetime. (16) Long-term is defined as the usable life of the device. (17) Per Figure 16, the maximum operational case temperature should be derated based on the micromirror landed duty cycle that the DMD experiences in the end application. Refer to Micromirror Landed-On/Landed-Off Duty Cycle for a definition of micromirror landed duty cycle. (18) Array and Window temperatures beyond those specified as long-term are recommended for short-term conditions only (power-up). Short-term is defined as cumulative time over the usable life of the device and is less than 500 hours. (19) For the DLP9000X, Figure 16 does not apply and the maximum temperature is as specified in table. (20) Temperature delta is the highest difference between the ceramic test point (TP1) and window test points (TP2) and (TP3) in Figure 15. (21) Refer to Thermal Information and Micromirror Array Temperature Calculation. LVDS INTERFACE ƒclock DLP9000 Clock frequency DCLK 400 MHz DLP9000X Clock frequency DCLK (11) 400 480 |VID| Input differential voltage (absolute value) (12) 100 400 600 mV VCM Common mode (12) 1200 mV VLVDS LVDS voltage (12) 0 2000 mV tLVDS_RSTZ Time required for LVDS receivers to recover from PWRDNZ 10 ns ZIN Internal differential termination resistance 95 105 Ω ZLINE Line differential impedance (PWB/trace) 90 100 110 Ω ENVIRONMENTAL (13) For Illumination Source Between 420 nm and 700 nm TARRAY DLP9000 Array temperature, Long–term operational (14) (15)(16) 10 40 to 65 (17) °C Array temperature, Short–term operational (14) (15)(18) 0 10 DLP9000X Array temperature, Long–term operational (14) (15)(16) 10 40 (19) Array temperature, Short–term operational (14) (15)(18) 0 10 TWINDOW DLP9000 Window Temperature test points TP2 and TP3, Long-term operational(16) 10 70 °C DLP9000X Window Temperature test points TP2 and TP3, Long-term operational(16) 10 40 |TDELTA| Absolute Temperature delta between the window test points (TP2, TP3) and the ceramic test point TP1(20) 10 °C ILLVIS Illumination Thermally Limited (21) mW/cm2 RH Relative Humidity (non-condensing) 95% ENVIRONMENTAL (13) For Illumination Source Between 400 nm and 420 nm TARRAY Array temperature, Long–term operational (14) (15)(16) 20 30 °C Array temperature, Short–term operational (14) (15)(18) 0 20 TWINDOW Window Temperature test points TP2 and TP3, Long-term operational (16) 30 °C |TDELTA| Absolute Temperature delta between the window test points (TP2, TP3) and the ceramic test point TP1(20) 10 °C ILLVIS Illumination 10 W/cm2 RH Relative Humidity (non-condensing) 95% ENVIRONMENTAL (13) For Illumination Source <400 nm and >700 nm TARRAY DLP9000 Array temperature, Long–term operational (14) (15)(16) 10 40 to 65 (17) °C Array temperature, Short–term operational (14) (15)(18) 0 10 DLP9000X Array temperature, Long–term operational (14) (15)(16) 10 40 (19) Array temperature, Short–term operational (14) (15)(18) 0 10 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |