165 / 215 page ![]() DS11626 Rev 9 165/216 L9678P, L9678P-S System voltage diagnostics 214 In case the voltage to be measured is not immediately available, the desired inputs for conversion have to be programmed by SPI in advance, to allow them to attain a stable voltage value. This case applies to the squib/pyroswitch resistance measurement and diagnostics (refer to Loop diagnostics control and results registers) and to the switch sensor measurement (refer to Section 9: DC sensor interface). CONVRDY_0 bit in GSW is equal to (NEWDATA_A or NEWDATA_B), while CONVRDY_1 bit in GSW corresponds to (NEWDATA_C or NEWDATA_D). Each NEWDATAx flag is asserted when conversion is finished and cleared when result is read out. However result is cleared only when a new result for that register is available. When a new request is received it is queued if other conversions are ongoing. The conversions are executed in the same order as their request arrived. The queue is 4 measures long so it's possible to send all 4 requests at the same time and then wait for the results. If a DIAGCTLRx command is received twice, the second conversion request will overwrite the previous one. Requests are sent to the L9678P IC via the ADC measurement Registers (ADCREQx) as shown in Table 11: Diagnostics control register (DIAGCTRLx) on page 165. All diagnostics results are available on the ADCRESx registers, when addressed by the related ADCREQx register (e.g. data requested by ADCREQA would be written to ADCRESA). Table 11. Diagnostics control register (DIAGCTRLx) ADC Request (ADCREQx) Voltage measurement selection ADC Results (ADCRESx) Bit [6:0] Hex Bit [9:0] 0 0 0 0 0 0 0 0 Unused 0 0 0 0 0 0 1 1 ADC Test Pattern 1 Ground reference 0 0 0 0 0 1 0 2 ADC Test Pattern 2 Full scale reference 0 0 0 0 0 1 1 3 DC Sensor ch. selected, Voltage DCSV_selected 0 0 0 0 1 0 0 4 DC Sensor ch. selected, Current DCSI_selected 0 0 0 0 1 0 1 5 DC Sensor ch. selected, Resistance(1) DCSV and DCSI selected 0 0 0 0 1 1 0 6 Squib/pyroswitch measurement loop selected Voutx 0 0 0 0 1 1 1 7 Bandgap reference Voltage VBGR 0 0 0 1 0 0 0 8 Bandgap reference monitor Voltage VBGM 0 0 0 1 0 0 1 9 Unused 0 0 0 1 0 1 0 10 Temperature Measurement TEMP 0 0 0 1 0 1 1 11 DC Sensor ch 0, Voltage DCSV_0 0 0 0 1 1 0 0 12 DC Sensor ch 1, Voltage DCSV_1 0 0 0 1 1 0 1 13 DC Sensor ch 2, Voltage DCSV_2 0 0 0 1 1 1 0 14 DC Sensor ch 3, Voltage DCSV_3 0 0 0 1 1 1 1 15 Unused 0 0 1 0 0 0 0 16 Unused 0 0 1 0 0 0 1 17 Unused |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |