| Electronic Components Datasheet Search |
|
TLC5926IPWPR Datasheet(PDF) 14 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TLC5926IPWPR Datasheet(HTML) 14 Page - Texas Instruments |
|
14 / 39 page ![]() TLC5926, TLC5927 SLVS677C – JULY 2008 – REVISED OCTOBER 2015 www.ti.com Feature Description (continued) Table 1. Open-Circuit Detection CONDITION OF STATE OF OUTPUT PORT ERROR STATUS CODE MEANING OUTPUT CURRENT Off IOUT = 0 mA 0 Detection not possible IOUT < IOUT,Th (1) 0 Open circuit On IOUT ≥ IOUT,Th (1) 1 Normal (1) IOUT,Th = 0.5 × IOUT,target (typical) 9.3.2 Short-Circuit Detection Principle (TLC5927 Only) The LED short-circuit detection compares the effective voltage level VOUT with the shorted-load detection threshold voltages VOUT,TTh and VOUT,RTh. If VOUT is above the VOUT,TTh threshold, the TLC5927 detects a shorted- load condition. If the VOUT is below VOUT,RTh threshold, no error is detected and the error bit is reset. This error status can be read as an error status code in the Special mode. For short-circuit error detection, a channel must be on. Table 2. Short-Circuit Detection CONDITION OF STATE OF OUTPUT PORT ERROR STATUS CODE MEANING OUTPUT VOLTAGE Off IOUT = 0 mA 0 Detection not possible VOUT ≥ VOUT,TTh 0 Short circuit On VOUT < VOUT,RTh 1 Normal 9.3.3 Overtemperature Detection and Shutdown The TLC592x is equipped with a global overtemperature sensor and 16 individual, channel-specific overtemperature sensors. • When the global sensor reaches the trip temperature, all output channels are shutdown, and the error status is stored in the internal Error Status register of every channel. After shutdown, the channels automatically restart after cooling down, if the control signal (output latch) remains on. The stored error status is not reset after cooling down and can be read out as the error status code in the Special mode. • When one of the channel-specific sensors reaches trip temperature, only the affected output channel is shut down, and the error status is stored only in the internal Error Status register of the affected channel. After shutdown, the channel automatically restarts after cooling down, if the control signal (output latch) remains on. The stored error status is not reset after cooling down and can be read out as error status code in the Special mode. For channel-specific overtemperature error detection, a channel must be on. The error status code is reset when the TLC592x returns to Normal mode. Table 3. Overtemperature Detection (1) STATE OF OUTPUT PORT CONDITION ERROR STATUS CODE MEANING Off IOUT = 0 mA 0 On Tj < Tj,trip global 1 Normal On → all channels Tj > Tj,trip global All error status bits = 0 Global overtemperature Off Tj < Tj,trip channel n 1 Normal On On → Off Tj > Tj,trip channel n Channel n error status bit = 0 Channel n overtemperature (1) The global shutdown threshold temperature is approximately 170°C. 14 Submit Documentation Feedback Copyright © 2008–2015, Texas Instruments Incorporated Product Folder Links: TLC5926 TLC5927 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |