| Electronic Components Datasheet Search |
|
TLC5926IPWPR Datasheet(PDF) 18 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TLC5926IPWPR Datasheet(HTML) 18 Page - Texas Instruments |
|
18 / 39 page ![]() 1 2 3 0 4 12 13 14 15 1 0 CLK OE(ED2) LE(ED1) SDI 16-Bit Configuration Code Bit 15 Bit 14 Bit 13 Bit 12 Bit 3 Bit 2 Bit 1 Bit 0 1 2 3 1 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 1 1 1 0 CLK OE(ED2) LE(ED1) SDO Data source of shift register Error Detection SDI SDI Error Status Code Bit 15 Bit 14 Bit 13 Bit 12 >2 µs TLC5926, TLC5927 SLVS677C – JULY 2008 – REVISED OCTOBER 2015 www.ti.com 9.4.3.1 Reading Error Status Code in Special Mode When OE(ED2) is pulled low while in Special mode, error detection and load error status codes are loaded into the Shift Register, in addition to enabling output ports to sink current. Figure 13 shows the timing sequence for error detection. The 0 and 1 signal levels are sampled at the rising edge of each CLK. At least three zeros must be sampled at the voltage low signal OE(ED2). Immediately after the second 0 is sampled, the data input source of the Shift Register changes to the 16-bit parallel Error Status Code register, instead of from the serial data on SDI. Normally, the error status codes are generated at least 2 μs after the falling edge of OE(ED2). The occurrence of the third or later 0 saves the detected error status codes into the Shift Register. Therefore, when OE(ED2) is low, the serial data cannot be shifted into TLC592x through SDI. When OE(ED2) is pulled high, the data input source of the Shift Register is changed back to SDI. At the same time, the output ports are disabled and the error detection is completed. Then, the error status codes saved in the Shift Register can be shifted out through SDO bit-by-bit along with CLK. Additionally, the new serial data can be shifted into TLC592x through SDI. While in Special mode, the TLC592x cannot simultaneously transfer serial data and detect LED load error status. Figure 13. Reading Error Status Code 9.4.4 Writing Configuration Code in Special Mode When in Special mode, the active high signal LE(ED1) latches the serial data in the Shift Register to the Configuration Latch, instead of the Output Latch. The latched serial data is used as the Configuration Code. The code is stored until power off or the Configuration Latch is rewritten. As shown in Figure 14, the timing for writing the Configuration Code is the same as the timing in the Normal Mode to latching output channel data. Both the Configuration Code and Error Status Code are transferred in the common 16-bit Shift Register. Users must pay attention to the sequence of error detection and current adjustment to avoid the the Error Status Code overwriting the Configuration Code. Figure 14. Writing Configuration Code 18 Submit Documentation Feedback Copyright © 2008–2015, Texas Instruments Incorporated Product Folder Links: TLC5926 TLC5927 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |