29 / 106 page ![]() Dual RPM-Based Linear Fan Controller with Hardware Thermal Shutdown Datasheet SMSC EMC2106 29 Revision 1.72 (11-01-07) DATASHEET The TACH / DRIVE bit in the Look Up Table Configuration Register MUST be set to ‘0’ or the TACH Target values will be incorrectly set. Setting this bit to ‘0’ ensures tha the settings will be RPM settings (Tachometer counts). APPLICATION NOTE: It is important that the TACH Target settings are in the proper format when using the RPM based Fan Speed Control Algorithm. 5.3 High Side Fan Driver The EMC2106’s contains a 5V, 600mA, linear high side fan driver to directly drive a 5V fan. By fully integrating the linear fan driver, the typical requirement for the discrete pass device and other external linearization circuitry is completely eliminated. The linear fan driver is driven by an 8-bit DAC providing better than 20mV resolution between steps. 5.3.1 Over Current Limit The High Side Fan Driver contains circuitry to allow for significant over current levels to accommodate transient conditions on the FAN pins. The over current limit is dependent upon the output voltage with the limit dropping as the voltage nears 0V. Table 5.3 Fan Controls Active for Operating Mode DIRECT SETTING MODE FSC MODE DIRECT SETTING W/ LUT MODE FSC W/ LUT MODE Fan Driver Setting (read / write) Fan Driver Setting (read only) Fan Driver Setting (read only) Fan Driver Setting (read only) EDGES[1:0] EDGES[1:0] (Fan Configuration) EDGES[1:0] EDGES[1:0] - RANGE[1:0] (Fan Configuration) - RANGE[1:0] (Fan Configuration) UPDATE[2:0] (Fan Configuration) UPDATE[2:0] (Fan Configuration) UPDATE[2:0] (Fan Configuration) UPDATE[2:0] (Fan Configuration) LEVEL (Spin Up Configuration) LEVEL (Spin Up Configuration) LEVEL (Spin Up Configuration) LEVEL (Spin Up Configuration) SPINUP_TIME[1:0] (Spin Up Configuration) SPINUP_TIME[1:0] (Spin Up Configuration) SPINUP_TIME[1:0] (Spin Up Configuration) SPINUP_TIME[1:0] (Spin Up Configuration) Fan Step Fan Step Fan Step Fan Step - Fan Minimum Drive Fan Minimum Drive Valid TACH Count Valid TACH Count Valid TACH Count Valid TACH Count - TACH Target (read / write) - TACH Target (read only) TACH Reading TACH Reading TACH Reading TACH Reading - - Look Up Table Drive / Temperature Settings (read only) Look up Table Drive / Temperature Settings (read only) - DRIVE_FAIL_CNT[1:0] and Drive Band Fail Registers - DRIVE_FAIL_CNT[1:0] and Drive Band Fail Registers |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |