| Electronic Components Datasheet Search |
|
EMC2106 Datasheet(PDF) 73 Page - SMSC Corporation |
|
|
|||||||||||||||||||||||||||||
EMC2106 Datasheet(HTML) 73 Page - SMSC Corporation |
|
73 / 106 page ![]() Dual RPM-Based Linear Fan Controller with Hardware Thermal Shutdown Datasheet SMSC EMC2106 73 Revision 1.72 (11-01-07) DATASHEET Bit 2 - 1 - ERR_RNGx[1:0] - Control some of the advanced options that affect the error window. When the measured fan speed is within the programmed error window around the target speed, then the fan drive setting is not updated. The algorithm will continue to monitor the fan speed and calculate necessary drive setting changes based on the error, however these changes are ignored. Bit 0 - LOWDRIVEx - Determines whether the tachometer measurement circuit will use the Tach Period Measurement method of fan speed measurement or the Tach Pulse Count Method of fan speed measurement. Setting this bit allows the use of low side fan drive circuits as shown in Figure 6.1 without requiring additional tachometer recovery circuitry. ‘0’ (default) - The tachometer signal must always be present when measuring the fan speed regardless of the measurement method. ‘1’ - Low side PWM drive circuits are supported and the tachometer signal does not need to be present at all times (which is common with such drive techniques). The tachometer measurement circuitry will use the Tach Pulse Count Method to determine the fan speed (contact SMSC for details on this operation). All tachometer related data is in the form of edge counts over a fixed time period. This method is significantly slower and the tachometer updates are non-continuous. Table 6.36 Derivative Options DER_OPTX[1:0] OPERATION 10 0 0 No derivative options used 01 Basic derivative. The derivative of the error from the current drive setting and the target is added to the iterative Fan Drive Register setting (in addition to proportional and integral terms) 10 Step derivative. The derivative of the error from the current drive setting and the target is added to the iterative Fan Drive Register setting and is not capped by the Fan Step Register. 11 Both the basic derivative and the step derivative are used effectively causing the derivative term to have double the effect of the derivative term (default). Table 6.37 Error Range Options ERR_RNGX[1:0] OPERATION 10 0 0 0 RPM (default) 0 1 50 RPM 1 0 100 RPM 1 1 200 RPM |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |