77 / 106 page ![]() Dual RPM-Based Linear Fan Controller with Hardware Thermal Shutdown Datasheet SMSC EMC2106 77 Revision 1.72 (11-01-07) DATASHEET APPLICATION NOTE: The UPDATE bits and Fan Step Register settings operate independently of the RPM based Fan Speed Control Algorithm and will always limit the fan drive setting. That is, if the programmed fan drive setting (either in determined by the RPM based Fan Speed Control Algorithm, the Look Up Table, or by manual settings) exceeds the current fan drive setting by greater than the Fan Step Register setting, the EMC2106 will limit the fan drive change to the value of the Fan Step Register. It will use the Update Time to determine how often to update the drive settings. APPLICATION NOTE: If the Fan Speed Control Algorithm is used, the default settings in the Fan Configuration 2 Register will cause the maximum fan step settings to be ignored. The Fan Step Registers are software locked. 6.30 Fan Minimum Drive Registers The Fan Minimum Drive Register stores the minimum drive setting for each RPM based Fan Speed Control Algorithm. The RPM based Fan Speed Control Algorithm will not drive the fan at a level lower than the minimum drive unless the target Fan Speed is set at FFh (see Section 6.33) During normal operation, if the fan stops for any reason (including low drive), the RPM based Fan Speed Control Algorithm will attempt to restart the fan. Setting the Fan Minimum Drive Registers to a setting that will maintain fan operation is a useful way to avoid potential fan oscillations as the control circuitry attempts to drive it at a level that cannot support fan operation. The Fan Minimum Drive Register is software locked. 6.31 Valid TACH Count Registers The Valid TACH Count Register stores the maximum TACH Reading Register value to indicate that the each fan is spinning properly. The value is referenced at the end of the Spin Up Routine to determine if the fan has started operating and decide if the device needs to retry. See Equation [5] for translating the count to an RPM. This register is only used when the FSC is active. Table 6.45 Minimum Fan Drive Registers ADDR R/W REGISTER B7B6B5 B4 B3 B2B1B0 DEFAULT 48h R/W Fan 1 Minimum Drive 128 643216 8 4 2 1 66h (40%) 88h R/W Fan 2 Minimum Drive 128 643216 8 4 2 1 66h (40%) Table 6.46 Valid TACH Count Registers ADDR R/W REGISTER B7B6 B5 B4B3B2 B1B0 DEFAULT 49h R/W Valid TACH Count 1 4096 2048 1024 512 256 128 64 32 F5h 89h R/W Valid TACH Count 2 4096 2048 1024 512 256 128 64 32 F5h |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |