Back Button EMC2106 Datasheet HTML 68Page - SMSC Corporation EMC2106 Datasheet HTML 69Page - SMSC Corporation EMC2106 Datasheet HTML 70Page - SMSC Corporation EMC2106 Datasheet HTML 71Page - SMSC Corporation EMC2106 Datasheet HTML 72Page - SMSC Corporation EMC2106 Datasheet HTML 73Page - SMSC Corporation EMC2106 Datasheet HTML 74Page - SMSC Corporation EMC2106 Datasheet HTML 75Page - SMSC Corporation EMC2106 Datasheet HTML 76Page - SMSC Corporation Next Button
Zoom Inzoom in Zoom Outzoom out
 72 / 106 page
background image
Dual RPM-Based Linear Fan Controller with Hardware Thermal Shutdown
Datasheet
Revision 1.72 (11-01-07)
72
SMSC EMC2106
DATASHEET
6.26
Fan Configuration 2 Registers
The Fan Configuration 2 Register controls the tachometer measurement and advanced features of the
RPM based Fan Speed Control Algorithm.
Bit 6 - EN_RRCx - Enables ramp rate control when the corresponding fan driver is operated in the
Direct Setting Mode or the Direct Setting with LUT mode.
‘0’ (default) - Ramp rate control is disabled. When the fan driver is operating in Direct Setting mode
or Direct Setting with LUT mode, the fan setting will instantly transition to the next programmed
setting.
‘1’ - Ramp rate control is enabled. When the fan driver is operating in Direct Setting mode or Direct
Setting with LUT mode, the fan drive setting will follow the ramp rate controls as determined by the
Fan Step and Update Time settings. The maximum fan drive setting step is capped at the Fan Step
setting and is updated based on the Update Time as given by Table 6.34.
Bit 5 - GLITCH_ENx - Disables the low pass glitch filter that removes high frequency noise injected
on the TACHx pin. If the LOWDRIVE bit is set, this bit is ignored and the filter is automatically disabled.
‘0’ - The glitch filter is disabled.
‘1’ (default) - The glitch filter is enabled.
Bits 4 - 3 - DER_OPTx[1:0] - Control some of the advanced options that affect the derivative portion
of the RPM based Fan Speed Control Algorithm as shown in Table 6.36.
Table 6.34 Update Time
UPDATE[2:0]
UPDATE TIME
21
0
00
0
100ms
00
1
200ms
01
0
300ms
0
1
1
400ms (default)
10
0
500ms
10
1
800ms
1
1
0
1200ms
1
1
1
1600ms
Table 6.35 Fan Configuration 1 Registers
ADDR
R/W
REGISTER
B7
B6
B5
B4
B3
B2
B1
B0
DEFAULT
43h
R/W
Fan 1
Configuration
2
-
EN_
RRC1
GLITCH
_EN1
DER_OPT1 [1:0]
ERR_RNG[1:0]
LOWD
RIVE1
38h
83h
R/W
Fan 2
Configuration
2
-
EN_
RRC2
GLITCH
_EN2
DER_OPT2 [1:0]
ERR_RNG[1:0]
LOWD
RIVE2
38h



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com