  ETA3006 Datasheet HTML 1Page - ETA SOLUTIONS CO. LIMITED ETA3006 Datasheet HTML 2Page - ETA SOLUTIONS CO. LIMITED ETA3006 Datasheet HTML 3Page - ETA SOLUTIONS CO. LIMITED ETA3006 Datasheet HTML 4Page - ETA SOLUTIONS CO. LIMITED ETA3006 Datasheet HTML 5Page - ETA SOLUTIONS CO. LIMITED ETA3006 Datasheet HTML 6Page - ETA SOLUTIONS CO. LIMITED ETA3006 Datasheet HTML 7Page - ETA SOLUTIONS CO. LIMITED ETA3006 Datasheet HTML 8Page - ETA SOLUTIONS CO. LIMITED ETA3006 Datasheet HTML 9Page - ETA SOLUTIONS CO. LIMITED Next Button
Zoom Inzoom in Zoom Outzoom out
 3 / 13 page
background image
ETA3006
www.eta-semi.com
3
Empower, Transcend, Achieve!
ETA3006 Rev 1.0
sleeping mode if don’t
detect unbalance
after TCHECK
TDONE
Finishing Timer
Maximum switching
skip before enter
sleep mode
62
mS
VKICK
Unbalance detection threshold
Balancing only work if
OVP>VBATP>UVLO
and VKICK Detected
between 2 cells
50
mV
VERROR
Balancing Accuracy
Error voltage between
2 cells after balancing
finish
-10
10
mV
BALANCE CONTROLLER
FREQ
Switching Frequency
PWM Clock
500
kHz
IAVERAGE
Average Inductor current Regulation RS = 50mΩ
1
A
RDS_ON
High side switch on Resistance
IAVERAGE =2A
40
mΩ
Low side switch on Resistance
IAVERAGE =2A
40
mΩ
BATTERY PROTECTION
TOP_OVP
Top Cell over voltage protection
threshold
V(BATP-BATC) Rising
5
V
TOP_OVP_HYST
TOP_OVP hysteresis
V(BATP-BATC) Falling
350
mV
BOT_OVP
Bottom Cell over voltage protection
threshold
V(BATC-BATN) Rising
5
V
BOT_OVP_HYST
BATC_OVP hysteresis
V(BATC-BATN) Falling
350
mV
TOP_PRECOND
Top battery precondition threshold
V(BATP-BATC) Rising
2.8
V
TOP_PREC_HYST
TOP_PRECOND hysteresis
V(BATP-BATC) Falling
150
mV
BOT_PRECOND
Bottom battery precondition
threshold
V(BATC-BATN) Rising
2.8
V
BOT_PREC_HYST
BOT_PRECOND hysteresis
V(BATC-BATN) Falling
150
mV
BALANCE PROTECTION
TOP_ILIM
Top cell drive current limit
RSense = 25mΩ;
DOWN direction:
V(BATP-BATC)> V(BATC-BATN)
4.5
A
BOT_ILIM
Lower cell drive current limit
RSense = 25mΩ;
UP direction:
V(BATP-BATC)< V(BATC-BATN)
4.5
A
THERMAL SHUTDOWN
TSD
Thermal shutdown
160
C
TSD_HYST
TSD Hysteresis
10
C



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com