| Electronic Components Datasheet Search |
|
AD5750 Datasheet(PDF) 19 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD5750 Datasheet(HTML) 19 Page - Analog Devices |
|
19 / 25 page ![]() Preliminary Technical Data AD5750 Rev. PrC | Page 19 of 25 0 1 1 0 0 +/-12.0V (20% over range) 0 1 1 0 1 +/-2.5v 0 1 1 1 0 N/A. If selected output will drive 0V. 0 1 1 1 1 N/A. If selected output will drive 0V. 1 0 0 0 0 4-20MA Internal Current Sense Resistor. 1 0 0 0 1 0-20MA Internal Current Sense Resistor. 1 0 0 1 0 0-24MA Internal Current Sense Resistor. 1 0 0 1 1 +/-20MA 1 0 1 0 0 +/-24MA 1 0 1 0 1 0-5V 1 0 1 1 0 0-10V 1 0 1 1 1 +/-5V 1 1 0 0 0 +/-10V 1 1 0 0 1 0-6.0V (20% over range) 1 1 0 1 0 0-12.0V (20% over range) 1 1 0 1 1 +/-6.0V (20% over range) 1 1 1 0 0 +/-12.0V (20% over range) 1 1 1 0 1 3.92ma – 20.4ma Internal Current Sense Resistor. 1 1 1 1 0 0ma – 20.4ma Internal Current Sense Resistor. 1 1 1 1 1 0ma – 24.5ma Internal Current Sense Resistor. Reset Resets the part to its Power on State Readback Operation Readback mode is invoked by selecting the correct device address (A2,A1,A0) and then setting the R/W bit to 1. By default the SDO pin is disabled, after having addressed the AD5750 for a read operation, setting R/W to 1 will enable the SDO pin and SDO data will be clocked out on the 5th rising edge of SCLK. After the data has been clocked out on SDO, a rising edge on SYNC will disable (tri- state) the SDO pin once again. STATUS and CONTROL register data will be both available during the same read cycle. See Table 7 below. Table 7. Input Shift Register Contents for a read operation MSB LSB D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 A2 A1 A0 1 0 R3 R2 R1 R0 CLRSEL OUTEN RSEL PEC Error Bit OVER TEMP IOUT Fault Vout Fault The STATUS bits are 4 read only bits. They are used to notify the user of specific fault conditions that have arisen, such as open or short circuit on the output, over temperature, or an interface error. If any one of these fault conditions occur a hardware FAULT is also asserted low which can be used as a hardware interrupt to the controller. Full explanation of fault conditions are given in the Features sections. Table 9. STATUS Bits Options Option Description PEC ERROR Bit Set if there is an Interface Error detected by CRC-8 Error Checking. See features section. VOUT FAULT Bit set if there is a short Circuit on VOUT pin. IOUT FAULT Bit set is there is an open circuit on IOUT pin. OVER TEMP This bit will be set if the AD5750 core temperature exceeds approx. 150°C. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |