| Electronic Components Datasheet Search |
|
AMC6821 Datasheet(PDF) 36 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
AMC6821 Datasheet(HTML) 36 Page - Texas Instruments |
|
36 / 54 page ![]() www.ti.com REGISTER DESCRIPTION DEVICE CONFIGURATION REGISTERS AMC6821 SBAS386C – MAY 2006 – REVISED JULY 2007 In this section, all interrupts are the interrupt signal through the SMBALERT pin, unless otherwise noted. Configuration Register 1 (Address 0x00, Value After Power-On Reset = 0xD4) BIT NAME R/W DEFAULT DESCRIPTION THERM interrupt enable. When this bit is set, the THERM interrupt is enabled. L-THERM = 1 or R-THERM = 1 causes an interrupt. When this bit is cleared ('0'), the 7 THERMOVIE R/W 1 THERM interrupt is disabled. When disabled, L-THERM = 1 or R-THERM = 1 does not assert the SMBALERT pin, but forces the THERM pin low. Power-on default = 1. 6 FDRC1 R/W 1 Fan driver control bit 1. Power-on default = 1. Refer to Table 15. 5 FDRC0 R/W 0 Fan driver control bit 0. Power-on default = 0. Refer to Table 15. Setting this pin to '1' enables the FAN-FAULT pin. Clearing this pin ('0') disables the 4 FAN-Fault-EN R/W 1 FAN-FAULT pin (always in Hi-Z). Power-on default = 1. PWM invert bit. When PWMINV = 0 (default), the PWM-Out pin goes low for 100% duty cycle (suitable for driving the fan using a PMOS device). Setting PWMINV to '1' makes 3 PWMINV R/W 0 the PWM-Out pin go high (with an external pull-up resistor) for 100% duty cycle (suitable for driving the fan using a NMOS device). Power-on default = 0. Fan RPM interrupt enable bit. Power-on default = 1. When FANIE = 1, the FAN-RPM interrupt is enabled. FANS = 1 or RPM-ALARM = 1 generates a FANORN interrupt, 2 FANIE R/W 1 making the SMBALERT pin go low. When FANIE = 0, a FAN-RPM interrupt is disabled. Fan out-of-range = 1 does not generate an interrupt. Setting this bit to '1' enables the interrupt from the SMBALERT pin. Clearing this bit ('0') 1 INT-EN R/W 0 disables the interrupt. Power-on default = 0. Temperature monitoring and fan speed monitoring. When START = 0 , only 0 START R/W 0 software-DCY control mode works; software-RPM and auto temperature control modes do not work. Table 15. Fan Driver Control Bits FDRC1 FDRC0 FUNCTION Maximum speed calculated control. The required duty cycle for remote temperature and 1 1 local temperature is calculated respectively. The larger value is used to control the fan. Auto remote-temperature-fan control. The PWM duty cycle is controlled by the remote 1 0 temperature. Power-on default mode. 0 0 Software DCY control. Host writes DCY register to set the PWM duty cycle directly. Software RPM control. Host writes the TACH setting register with the value corresponding 0 1 to the desired RPM. The device measures the actual RPM and adjusts the PWM duty cycle to maintain the fan speed to the target value. 36 Submit Documentation Feedback Copyright © 2006–2007, Texas Instruments Incorporated Product Folder Link(s): AMC6821 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |