| Electronic Components Datasheet Search |
|
AMC6821 Datasheet(PDF) 29 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
AMC6821 Datasheet(HTML) 29 Page - Texas Instruments |
|
29 / 54 page ![]() www.ti.com ReadLocal Temperature No Yes LTH=1, LTO=1 Yes No No Temperature ³ Local-Critical-Temp LTC=1, isLow OVR LTL=1, LTO=1 Yes RTL=1, RTO=1 Yes ReadRemote Temperature RTH=1, RTO=1 Yes No RTC=1, OVR isLow Yes No No (UpdateDCYwiththeratedefinedbythe bits[RATE2: 0]oftheDCYrampregister. RATE Temperature ³ Remote-Critical-Temp Temperature ³ Remote-High-Temp-Limit Temperature £ Local-Low-Temp-Limit Temperature ³ Local-High-Temp-Limit Temperature £ Remote-Low-Temp-Limit CalculateNewDCYfortheRemote FanTemperatureControl Yes CalculateDCYfortheremotefantemperaturecontrol andlocalfantemperaturecontrol,respectively. UsethelargeroneasthenewDCY. No RemoteFanTemperatureControlMode UpdateDCY (RemoteFanTemperatureControl) (Maximumfastspeedcalculatedcontrol) UpdateDCY? Yes No ThetemperatureupdatingratemaybefasterthantheDCYupdatingrate. AMC6821 SBAS386C – MAY 2006 – REVISED JULY 2007 When the actual duty cycle is different from the desired value, the duty cycle is adjusted automatically. When the RAMPE bit of the DCY-RAMP Register is cleared ('0'), the duty cycle changes to the desired value immediately after being calculated. When the RAMPE bit is '1', the duty cycle changes to the new value gradually. The DCY-RAMP Register specifies how quickly the duty cycle changes. The duty cycle can be checked every 0.0625 second to every eight seconds, depending on the bits [RATE2:RATE0] bits. It changes 1/255(0.392%) to 4/255 (1.57%) each time, depending on the bits [STEP1:STEP0] bits. When the difference between the actual value and the target value is equal to or less than the adjustment threshold (as defined by the bits [THRE1:THRE0] bits), the adjustment finishes. See the DCY-RAMP Register for details. When the TACH monitoring is enabled (TACH-EN bit, bit 2 of 0x02, is set to '1') and the TACH-MODE bit (bit 1 of 0x02) is cleared ('0'), the duty cycle is forced to 0% when the calculated value is less than 7%. If the TACH monitoring is disabled (TACH-EN = 0) or the TACH-MODE bit is set ('1'), the duty cycle is always set to the calculated value even if the value is less than 7%. Figure 29. Temperature Monitoring Flow Chart Copyright © 2006–2007, Texas Instruments Incorporated Submit Documentation Feedback 29 Product Folder Link(s): AMC6821 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |