29 / 54 page ![]() CS5460A DS487F4 29 Note that when the calibration command is sent to the CS5460A, the device must not be performing A/D conversions (in either of the two acquisitions modes). If the CS5460A is running A/D conver- sions/computations in the ‘continuous computation cycles’ acquisition mode (C = 1), the Pow- er-Up/Halt Command must be issued first to termi- nate A/D conversions/computations. If the CS5460A is running A/D conversions/computa- tions in the ‘single computation cycle’ data acquisi- tion mode (C = 0), the Power-Up/Halt Command must be issued first (unless the computation cycle has completed) before executing any calibration sequence. The calibration sequences will not run if the CS5460A is running in either of the two avail- able acquisition modes. 3.8.4 Calibration Signal Input Level For both the voltage and current channels, the dif- ferential voltage levels of the calibration signals must be within the specified voltage input limits (re- fer to “Differential Input Voltage Range” in Section 1., Characteristics & Specifications). For the volt- age channel the peak differential voltage level can never be more than 500 mVP-P. The same is true for the current channel if the current channel input PGA is set for 10x gain. If the the current channel’s PGA gain is set to 50x, then the current channel’s input limits are 100 mVP-P. Note that for the AC/DC gain calibrations, there is an absolute limit on the RMS/DC voltage levels (re- spectively) that are selected for the voltage/current channel gain calibration input signals. The maxi- mum value that the gain register can attain is 4. Therefore, for either channel, if the voltage level of a gain calibration input signal is low enough that it causes the CS5460A to attempt to set either gain register higher than 4, the gain calibration result will be invalid, and after this occurs, all CS5460A results obtained when the part is running A/D con- versions will be invalid. 3.8.5 Calibration Signal Frequency The frequency of the calibration signals must be less than 1 kHz (assume MCLK/K = 4.096 MHz and K = 1). Optimally, the frequency of the calibra- tion signal will be at the same frequency as the fun- damental power line frequency of the power system that is to be metered. 3.8.6 Input Configurations for Calibrations Figure 16 shows the basic setup for gain calibra- tion. If a DC gain calibration is desired, a positive DC voltage level must be applied, such that it truly represents the absolute maximum peak instanta- neous voltage level that needs to be measured across the inputs (including the maximum over-range level that must be accurately mea- sured). In other words, the input signal must be a positive DC voltage level that represents the de- sired absolute peak full-scale value. However, in many practical power metering situations, an AC signal is preferred over a DC signal to calibrate the gain. To perform AC gain calibration instead of DC, an AC reference signal should be applied that is set to the desired maximum RMS level. Because the voltage/current waveforms that must be mea- sured in most power systems are approximately si- nusoidal in nature, the RMS levels of the AC gain calibration input signals may need to be set signif- icantly lower than the voltage/current channel’s maximum DC voltage input level. This must be done in order to avoid the possibility that the peak values of the AC waveforms that are to be mea- sured will not register a value that would be outside the available output code range of the voltage/cur- rent A/D converters. For example, on the voltage channel, if the Voltage Channel Gain Register is set to it’s default power-on value of 1.000... before calibration, then the largest pure sinusoidal wave- form that can be used in AC calibration is one whose RMS-value is ~0.7071 of the value of the voltage channel’s peak DC input voltage value of 500 mVP-P. Thus the maximum value of the input sinusoid would be ~176.78 mV (rms). But in many practical power metering situations, the RMS volt- age input level of the AC gain calibration signal may be reduced even further, to allow for some over-ranging capability. A typical sinusoidal cali- bration value which allows for reasonable over-range margin would be 0.6 of the voltage/cur- rent channel’s maximum input voltage level. For the voltage channel, such a sine-wave would have a value of 0.6 x 250 mVrms =150 mVrms. For the offset calibrations, there is no difference between the AC and DC calibration signals that must be supplied: simply connect the “+” and “-’ |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |