| Electronic Components Datasheet Search |
|
ATA5423-PLSW Datasheet(PDF) 59 Page - ATMEL Corporation |
|
|
|||||||||||||||||||||||||||||
ATA5423-PLSW Datasheet(HTML) 59 Page - ATMEL Corporation |
|
59 / 100 page ![]() 59 4841D–WIRE–10/07 ATA5423/ATA5425/ATA5428/ATA5429 In the presence of a valid transmitter signal, T Bit-check is dependent on the frequency of that sig- nal, f Signal, and the count of the bits, NBit-check. A higher value for NBit-check therefore results in a longer period for T Bit-check, requiring a higher value for the transmitter pre-burst, TPreburst. 9.1.7 Receiving Mode If the bit check was successful for all bits specified by N Bit-check, the transceiver switches to receiving mode. To activate a connected microcontroller, the bits VSOUT_EN and CLK_ON in control register 3 are set to “1”. An interrupt is issued at pin IRQ if the control bits T_MODE = 0 and P_MODE = 0. If the transparent mode is active (T_MODE = 1) and the level on pin CS is low (no data transfer via the serial interface), the RX data stream is available on pin SDO_TMDO (Figure 9-8). Figure 9-8. Receiving Mode (TMODE = 1) If the transparent mode is inactive (T_MODE = 0), the received data stream is buffered in the TX/RX data buffer (see Figure 9-9 on page 60). The TX/RX data buffer is only usable for Manchester and Bi-phase coded signals. It is always possible to transfer the data from the data buffer via the 4-wire serial interface to a microcontroller (see Figure 8-1 on page 49). Buffering of the data stream: After a successful bit check, the transceiver switches from bit-check mode to receiving mode. In receiving mode the TX/RX data buffer control logic is active and examines the incoming data stream. This is done, as in the bit check, by subsequent time frame checks where the distance between two edges is continuously compared to a programmable time window as illustrated in Figure 9-9 on page 60. Only two time differences between two edges in Manchester and Bi-phase coded signals are valid (T and 2T). The limits for T are the same as used for the bit check. They can be programmed in control register 5 and 6 (Lim_min, Lim_max). The limits for 2T are calculated as follows: Lower limit of 2T: Upper limit of 2T: If the result of Lim_min_2T or Lim_max_2T is not an integer value, it will be rounded up. SDO_TMDO Demod_Out Bit check ok Preburst Byte 2 Byte 1 Start bit '0' '0' '0' '0' '0' '0' '0' '0' '0' '1' '1' '0' '0' '0' '0' '0' '0' '1' '1' '1' '1' '0' '0' '1' '1' '0' '1' '0' '1' '1' '0' '0' Bit-check mode Receiving mode Byte 3 Lim_min_2T Lim_min Lim_max + () Lim_max Lim_min – ()/2 – = T Lim_min_2T Lim_min_2T T XDCLK × = Lim_max_2T Lim_min Lim_max + () Lim_max Lim_min – ()/2 + = T Lim_max_2T Lim_max_2T - 1 () T XDCLK × = |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |