Back Button TLC320AC02C Datasheet HTML 68Page - Texas Instruments TLC320AC02C Datasheet HTML 69Page - Texas Instruments TLC320AC02C Datasheet HTML 70Page - Texas Instruments TLC320AC02C Datasheet HTML 71Page - Texas Instruments TLC320AC02C Datasheet HTML 72Page - Texas Instruments TLC320AC02C Datasheet HTML 73Page - Texas Instruments TLC320AC02C Datasheet HTML 74Page - Texas Instruments TLC320AC02C Datasheet HTML 75Page - Texas Instruments TLC320AC02C Datasheet HTML 76Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 72 / 84 page
background image
A–2
CONTROL FUNCTION OF CONTROL BITS (Continued)
BITS
TERMINALS
D01
D00
FC1
FC0
0
1
1
1
On the next falling edge of FS, the AIC receives DAC data D15 – D02 to DIN and
transmits the ADC data D15 – D00 from DOUT.
The phase adjustment is determined by the state of D01 and D00 such that on the
next rising edge of FS, the next ADC/DAC sampling time occurs later by the number
of MCLK periods determined by the value contained in the A
′ register. When the A′
register value is negative, FS occurs earlier.
When FC0 and FC1 are both taken high, the AIC initiates a secondary FS to receive
a secondary control word at DIN. The secondary frame sync occurs at 1/2 the
sampling time as measured from the falling edge of the primary FS.
1
0
1
1
On the next falling edge of FS, the AIC receives DAC data D15 – D02 at DIN and
transmits the ADC data D15 – D00 from DOUT.
The phase adjustment is determined by the state of D01 and D00. On the next rising
edge of FS, the next ADC/DAC sample time occurs earlier by the number of MCLK
periods determined by the value contained in the A
′ register. When the A′ register
value is negative, FS occurs later.
When FC0 and FC1 are both taken high, the AIC initiates a secondary FS to receive
a secondary control word at DIN. The secondary frame sync occurs at 1/2 the
sampling time as measured from the falling edge of the primary FS.
1
1
1
1
On the next falling edge of the primary FS, the AIC receives DAC data D15 – D02 at
DIN and transmits the ADC data D15 – D00 from DOUT.
When FC1 and FC0 are both high or D01 and D00 are both high, the AIC initiates a
secondary FS to receive a secondary control word at DIN. The secondary FS occurs
at 1/2 the sampling time measured from the falling edge of the primary FS.
1
1
0
1
On the next falling edge of FS, the AIC receives DAC data D15 – D02 to DIN and
transmits the ADC data D15 – D00 from DOUT.
When D00 and D01 are high, the AIC initiates a secondary FS to receive a secondary
control word at DIN. The secondary frame sync occurs at 1/2 the sampling time as
measured from the falling edge of the primary FS.
The phase adjustment is determined by the state of FC1 and FC0 such that on the
next rising edge of FS, the next ADC/DAC sampling time occurs later by the number
of MCLK periods determined by the value contained in the A
′ register. When the A′
register value is negative, FS occurs earlier.
1
1
1
0
On the next falling edge of FS, the AIC receives DAC data D15 – D02 to DIN and
transmits the ADC data D15 – D00 from DOUT.
When D00 and D01 are high, the AIC initiates a secondary FS to receive a secondary
control word at DIN. The secondary frame sync occurs at 1/2 the sampling time as
measured from the falling edge of the primary FS.
The phase adjustment is determined by the state of FC1 and FC0 such that on the
next rising edge of FS, the next ADC/DAC sampling time occurs later by the number
of MCLK periods determined by the value contained in the A
′ register. When the A′
register value is negative, FS occurs earlier.
1
1
1
1
On the next falling edge of FS, the AIC receives DAC data D15 – D02 at DIN and
transmits the ADC data D15 – D00 from DOUT.
When FC1 and FC0 are both high or D01 and D00 are both high, the AIC initiates a
secondary FS to receive a secondary control word at DIN. The secondary FS occurs
at 1/2 the sampling time measured from the falling edge of the primary FS.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com