17 / 29 page ![]() SC824 17 Applications Information (continued) When V EN_NTC < RT NTC_DIS×VVSYS (nominally 10% of VVSYS), the SC824 charger is disabled. This threshold allows the EN_NTC pin to be used as a disable pin, allowing the system controller to asynchronously disable or reset the device by pulling EN_NTC to ground. When V EN_NTC < RT NTC_DIS×VVSYS, the charger is turned off, the charge timer is reset, and the STAT1 status output is turned off. While disabled, the VIN input UVLO and OVP threshold detectors remain active, and the STAT0 pin continues to indicate whether the VIN input voltage is valid for charging. No-Battery operation is selected when the battery (along with the thermistor) is removed, determined by the NTC pin exceeding RT NTC_NBR × V VSYS , which is 95% of the VSYS pin voltage. In No-Battery operation, the charge timer is disabled and the output is regulated to V CV , subject to the output current limit determined by the selected mode and IPRGM pin resistance to GND. The STAT0 output remains asserted to indicate that the charging source is present and STAT1 is released. When returning to normal charging (by reinstalling the battery and thermistor), the timer is reset. The response of the SC824 to an EN_NTC pin voltage above the NTC Cold Fault threshold (but below RT NTC_NBR ) or below the low NTC Hot Fault threshold (but above VT NTC_DIS) is the same. Therefore the EN_NTC network can be configured with the battery pack thermistor between EN_NTC and VSYS, and a fixed resistor between EN_NTC and ground, reversing the designation of the hot and cold thresholds. This configuration may be used to disable the charger when the battery pack is removed. For detailed design guidance for ratiometric NTC inter- faces, including thermistor selection guidelines, see the Semtech Application Note AN–PM–0801, NTC Thermistor Network Design for Ratiometric Thresholds. Charge Timer The SC824 provides a multi-stage charge timer. Each stage of the charge cycle is timed separately, in compli- ance with IEEE Std. 1725-2006, Section 7.3.5. The pre-charge stage timer indicates a fault and halts charging if the battery voltage has not exceeded the pre- charge threshold within 45 minutes after the start of the charge cycle. The pre-charge stage timer is active even if the timer function has been disabled. When the battery voltage exceeds the pre-charge thresh- old, the timer is reset and begins timing the CC stage. The CC stage timer indicates a fault and halts charging if the battery voltage has not reached V CV within the CC stage fault timer duration (t CCF ). The CC stage timer is not active if the timer function has been disabled. An internally programmed CC stage duration of three hours can be selected by connecting RTIME directly to VSYS. Or it can be programmed from two hours to 16 hours by selection of the resistance from the RTIME pin to ground, as shown in the Block Diagram. The broad CC stage timer programming range permits timer-protected charging of large batteries with small charging currents, such as in USB low power mode charging. The value of t CCF is programmed according to Figures 4a and 4b. Each figure shows the nominal t CCF duration versus nominal R RTIME resistance as the center plot and two theo- retical limit plots indicating maximum and minimum t CCF duration versus nominal programming resistance. These plots are derived from models of the expected worst-case contribution of error sources that depend on programmed current. The t CCF tolerance range includes the uncertainty due to 1% tolerance resistors. The dots on each plot indi- cate the currents obtained with EIA E96 standard value 1% tolerance resistors. Figures 4a and 4b show low and high resistance ranges, respectively. When the battery voltage has risen to V CV , the CC timer stage ends, the timer is reset, and the CV timer stage begins. The CV stage timer is set to expire in three hours using a fixed-duration internal timer. Upon termination by current (10% of fast charge current) or expiration of the CV stage timer (whichever occurs first), end-of-charge is indicated by releasing STAT1 and the timer is reset. Note that CV stage time-out is not a fault, but rather is regarded as termination by another means. This alternative termi- nation-by-time behavior ensures termination in the case that the minimum load current exceeds the programmed termination current. Following termination, by current or by timer CV stage time-out, the post-termination top-off timer stage begins. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |