| Electronic Components Datasheet Search |
|
MAX16929BGUI Datasheet(PDF) 14 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX16929BGUI Datasheet(HTML) 14 Page - Maxim Integrated Products |
|
14 / 25 page ![]() ���������������������������������������������������������������� Maxim Integrated Products 14 MAX16929 Automotive TFT-LCD Power Supply with Boost Converter and Gate Voltage Regulators The external p-channel FET controlled by GATE protects the output during fault conditions and provides True Shutdown of the converter. Connect a pullup resistor between GATE and INA (see the Boost Converter section to select the value for the pullup resistor). Under normal operation, GATE turns on the p-channel FET, connecting the supply to the boost input. During a fault condition or in shutdown, GATE is off and the pullup resistor turns off the p-channel FET, disconnecting the supply from the boost input. Spread-Spectrum Modulation The high-frequency 2.2MHz operation of the boost con- verter keeps switching noise outside of the AM band. The device achieves enhanced EMI performance by modu- lating the switching frequency by Q4%. The modulating signal is pseudorandom and changes each switching period (i.e., fSS = 2.2MHz). Startup Immediately after power-up, coming out of shutdown, or going into autoretry, the boost converter performs a short-circuit detection test on the output by connecting the input (INA) to the switching node (LXP) through an internal 50I resistor. If the resulting voltage on LXP exceeds 1.2V, the device turns on the external pMOS switch by pulling GATE low. The boost output ramps to its final value in 15ms. An overloaded or shorted output is detected if the result- ing voltage on LXP is below 1.2V. The external pMOS switch remains off and the converter does not switch. After the fault blanking period of 238ms, the device pulls PGOOD low and starts the autoretry timer. The short-circuit detection feature places a lower limit on the output load of approximately 46I when the input voltage is 3V. Fault Conditions and PGOOD PGOOD signals whether all the regulators and the boost converter are operating normally. PGOOD is an open- drain output that pulls low if any of the following faults occur: 1) The boost output voltage falls below 85% of its set value. 2) The positive-gate voltage regulator output (VGH) falls below 85% of its set value. 3) The negative-gate voltage regulator output (VGL) falls below 85% of its set value. 4) The LXP voltage is greater than 21V (typ). 5) The positive charge-pump voltage (VCP) is greater than 30.5V (typ). 6) The 1.8V/3.3V regulator output voltage falls below 85% of its nominal value. 7) The buck output voltage falls below 92% of its nominal value. If any of the first three fault conditions persists for longer than the 238ms fault blanking period, the device pulls PGOOD low, turns off all outputs, and starts the autoretry timer. If either condition 4 or 5 occurs, the device pulls PGOOD low and turns off all outputs immediately. The device initi- ates startup only after the fault has cleared. If condition 6 occurs, the device pulls PGOOD low, but does not turn off any of the outputs. During startup, PGOOD is masked and goes high as soon as the 1.8V/3.3V regulator controller turns on. This regulator turns on as soon as VINA exceeds the INA undervoltage lockout threshold. Autoretry When the autoretry counter finishes incrementing after 1.9s, the device attempts to turn on the boost converter and gate voltage regulators in the order shown in Table 1. The device continues to autoretry as long as the fault condition persists. A fault on the 1.8V/3.3V regulator output causes PGOOD to go low, but does not result in the device shutting down and going into autoretry. Current Limit The effective current limit of the boost converter is reduced by the internally injected slope compensation by an amount dependent on the duty cycle of the converter. The effective current limit is given by: -12 LIM(EFF) LIM_DC_0 COMPI D I =192 10 I C × × × where ILIM(EFF) is the effective current limit, ILIM_DC_0 = 1.1A or 2.2A depending on the boost converter current- limit option, D is the duty cycle of the boost converter, and CCOMPI is the value of the capacitor at the COMPI input. Estimate the duty cycle of the converter using the formulas shown in the Design Procedure section. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |