18 / 19 page ![]() 18 ・All specifications are subject to change without notice. SWS 600L, 1000L 7. External Fuse Rating Refer to the following fuse rating when selecting the external fuses that are to be used on input line. Surge current flows when line turns on. Use slow-blow or time-lag type fuse, not fast-blow fuse. Fuse rating is specified by in-rush current value at line turn-on. Do not select the fuse according to input current (RMS.) values under the actual load condition. SWS600L : 15A SWS1000L : 20A 8. Fan life expectancy The Fan-life has limitation. Therefore, periodic maintenance by exchanging the life-expired fan is required for the power supply. The following figure shows the life of fan. SWS600L, SWS1000L Fan acoustic noise: SWS600L, SWS1000L: build in fan speed control circuit . SWS600L : 45dB[A] at room temperature, 50dB[A] at high ambient temperature. SWS1000L: 53dB[A] at room temperature, 55dB[A] at high ambient temperature SWS600L/RF: 50dB[A] SWS600L/RF, SWS1000L/RF 1 10 0 50 100 Ambient temperature ( ℃ ) 100 50 0 1 10 Ambient temperature ( ℃ ) 9. Special instructions for IEC/EN/UL/CSA 60601-1 (SWS1000L only) (1) These products are designed for continuous operation within an overall enclosure, and must be mounted such that access to the mains terminals is restricted. See Clause 16, IEC/EN/UL60601-1. (2) These products are NOT suitable for use in the presence of flammable anaesthetic mixtures with air or wish oxygen or nitrous oxide. (3) These products are classed as ordinary equipment accord- ing to IEC/EN/UL60601-1 and are NOT protected against the ingress of water. (4) Connect only apparatus complying with IEC/EN/UL60601-1 to the signal ports. (5) Except for permanently installed equipment as defined in Clause 57.6 of IEC/EN/UL60601-1 the overall equipment in which these products are installed must have double pole fusing on the input mains supply. The products themselves have single pole fusing in the live line. (6) When the PSU is installed within medical equipment an all pole mains input disconnect device must be fitted. (7) Reference should be made to local regulations concerning the disposal of these products at the end of their useful life. (8) These products have not been assessed to IEC/EN60601-1-2 (EMC) but EMC test data is available from NEMIC-LAMBDA (S) PTE LTD. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |