Back Button ADP5061 Datasheet HTML 35Page - Analog Devices ADP5061 Datasheet HTML 36Page - Analog Devices ADP5061 Datasheet HTML 37Page - Analog Devices ADP5061 Datasheet HTML 38Page - Analog Devices ADP5061 Datasheet HTML 39Page - Analog Devices ADP5061 Datasheet HTML 40Page - Analog Devices ADP5061 Datasheet HTML 41Page - Analog Devices ADP5061 Datasheet HTML 42Page - Analog Devices ADP5061 Datasheet HTML 43Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 39 / 44 page
background image
Data Sheet
ADP5061
Rev. 0 | Page 39 of 44
FACTORY PROGRAMMABLE OPTIONS
CHARGER OPTIONS
Table 38 to Table 50 list the factory programmable options of the ADP5061. In each of these tables, the selection column represents the
default setting of Model ADP5061ACBZ-2-R7.
Table 38. Default Termination Voltage
Option
Selection
000 = 4.20 V
000 = 4.20 V
010 = 3.70 V
011 = 3.80 V
100 = 3.90 V
101 = 4.00 V
110 = 4.10 V
111 = 4.40 V
Table 39. Default Fast Charge Current
Option
Selection
000 = 500 mA
001 = 300 mA
010 = 550 mA
011 = 600 mA
100 = 750 mA
100 = 750 mA
101 = 900 mA
110 = 1300 mA
111 = 1300 mA
Table 40. Default End of Charge Current
Option
Selection
000 = 52.5 mA
000 = 52.5 mA
001 = 72.5 mA
010 = 12.5 mA
011 = 32.5 mA
100 = 142.5 mA
101 = 167.5 mA
110 = 92.5 mA
111 = 117.5 mA
Table 41. Default Trickle to Fast Charge Threshold
Option
Selection
00 = 2.5 V
00 = 2.5 V
01 = 2.0 V
10 = 2.9 V
11 = 2.6 V
Table 42. Default System Voltage
Option
Selection
000 = 4.3 V
001 = 4.4 V
010 = 4.5 V
011 = 4.6 V
100 = 4.7 V
101 = 4.8 V
110 = 4.9 V
111 = 5.0 V
111 = 5.0 V
Table 43. Thermistor Resistance
Option
Selection
0 = 10 kΩ
0 = 10 kΩ
1 = 100 kΩ
Table 44. Thermistor Beta Value
Option
Selection
0100 = 3150
0100 = 3150
0101 = 3350
0110 = 3500
0111 = 3650
1000 = 3850
1001 = 4000
1010 = 4200
1011 = 4400
Table 45. DIS_IC1 Mode Select
Option
Selection
0 = DIC_IC1 mode select, VINx current = 280 µA,
ISO_B can float, no leak to ISO_Bx
0
1 = DIC_IC1 mode select, VINx current = 110 µA,
supply switch leaks from VINx to ISO_Bx
Table 46. Trickle or Fast Charge Timer Fault Operation
Option
Selection
0 = after timeout LDO off, charging off
1 = after timeout LDO mode active, charging
off
1 = LDO mode
active



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com