Electronic Components Datasheet Search
  English  ▼

X  

SST38VF166 Datasheet(PDF) 6 Page - Silicon Storage Technology, Inc

Part # SST38VF166
Description  16 Megabit FlashBank Memory
PDF  50 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  SST [Silicon Storage Technology, Inc]
Direct Link  http://www.sst.com/
Logo SST - Silicon Storage Technology, Inc

SST38VF166 Datasheet(HTML) 6 Page - Silicon Storage Technology, Inc

Back Button SST38VF166 Datasheet HTML 2Page - Silicon Storage Technology, Inc SST38VF166 Datasheet HTML 3Page - Silicon Storage Technology, Inc SST38VF166 Datasheet HTML 4Page - Silicon Storage Technology, Inc SST38VF166 Datasheet HTML 5Page - Silicon Storage Technology, Inc SST38VF166 Datasheet HTML 6Page - Silicon Storage Technology, Inc SST38VF166 Datasheet HTML 7Page - Silicon Storage Technology, Inc SST38VF166 Datasheet HTML 8Page - Silicon Storage Technology, Inc SST38VF166 Datasheet HTML 9Page - Silicon Storage Technology, Inc SST38VF166 Datasheet HTML 10Page - Silicon Storage Technology, Inc Next Button
Zoom Inzoom in Zoom Outzoom out
 6 / 50 page
background image
6
Data Sheet
16 Megabit FlashBank Memory
SST38VF166
©2001 Silicon Storage Technology, Inc.
327-3 2/01
S71065
The requirements for JEDEC compliant SDP are in byte
format. The SST38VF166 is organized by word; therefore,
the contents of DQ8 to DQ15 are “Don’t Care” during any
SDP (3-word or 6-word) command sequence.
During the SDP load command sequence, the SDP load
cycle is suspended when WE# is high. This means a read
may occur to any other bank during the SDP load
sequence.
The SDP load sequence is bank specific, i.e., the same
BE# must be low for each bus cycle. If the command
sequence is aborted, e.g., a different BE# is brought low
(except for Read operation with WE# high), an incorrect
address is loaded, or incorrect data is loaded, the device
will return to the Read mode within TRC of execution of the
load error.
Concurrent Read and Write Operations
The SST38VF166 provides the unique benefit of being
able to read any bank, while simultaneously writing, eras-
ing, or programming one other bank. This allows data alter-
ation code to be executed from one bank, while altering the
data in another bank. The following table lists all valid
states.
Note: For the purposes of this table, write means to Word-Write;
Block-, Sector-, or Chip-Erase; or Word-Program as applica-
ble to the appropriate bank.
SST does not recommend that any two of the bank enable
signals BE#1, BE#2 or BE#3 be simultaneously asserted.
The device will ignore all SDP commands and toggling of
WE# when an Erase, Program, or Write operation is in
progress. Note, both Product Identification and the Com-
mon Flash Interface entry commands use SDP; therefore,
these commands will also be ignored while an Erase, Pro-
gram, or Write operation is in progress.
Product Identification
The product identification mode identifies the device manu-
facturer as SST and provides a code to identify each bank.
The manufacturer ID is the same for each bank; however,
each bank has a separate device ID. Each bank is individu-
ally accessed using the applicable BE# and a software
command. Users may wish to use the device ID operation
to identify the write algorithm requirements for each bank.
For details, see Table 6 or 7 for software operation and Fig-
ures 27, 28, or 29 for timing waveforms.
Device IDs are unique to each bank. Should a chip ID be
required, any of the bank IDs may be used as the chip ID.
While in the read software ID mode or CFI mode, no other
operation is allowed until after exiting these modes.
Product Identification Mode Exit
In order to return to the standard Read mode, the Product
Identification mode must be exited. Exit is accomplished by
issuing the Software ID exit command, which returns the
device to normal operation. This command may also be
used to reset the device to the Read mode after any inad-
vertent transient condition that apparently causes the
device to behave abnormally, e.g., not read correctly. For
details, see Table 6 or 7 for software operation and Figures
30, 31, or 32 for timing waveforms.
TABLE
1: CONCURRENT READ/WRITE STATE
Flash Bank 1
Flash Bank 2
E2 Bank
Read
No Operation
Write
Read
Write
No Operation
Write
Read
No Operation
No Operation
Read
Write
Write
No Operation
Read
No Operation
Write
Read
T1.0 327
TABLE
2: PRODUCT IDENTIFICATION
Address
Data
Manufacturer’s ID
0000H
00BFH
Device ID
Flash Bank 1
0001H
2791H
Flash Bank 2
0001H
2792H
E2 Bank
0001H
2793H
T2.1 327



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com