27 / 30 page ![]() TDA7562B Examples of bytes sequence Doc ID 17984 Rev 2 27/30 7 Examples of bytes sequence 1 - Turn-on diagnostic - Write operation 2 - Turn-on diagnostic - Read operation The delay from 1 to 2 can be selected by software, starting from 1ms 3a - Turn-on of the power amplifier with 30 dB gain, mute on, diagnostic defeat. 3b - Turn-off of the power amplifier 4 - Offset detection procedure enable 5 - Offset detection procedure stop and reading operation (the results are valid only for the offset detection bits (D2 of the bytes DB1, DB2, DB3, DB4). ● The purpose of this test is to check if a D.C. offset (2 V typ.) is present on the outputs, produced by input capacitor with anomalous leakage current or humidity between pins. ● The delay from 4 to 5 can be selected by software, starting from 1ms 6 - Current detection procedure start (the AC inputs must be with a proper signal that depends on the type of load) 7 - Current detection reading operation (the results valid only for the current sensor detection bits - D5 of the bytes DB1, DB2, DB3, DB4). ● During the test, a sinus wave with a proper amplitude and frequency (depending on the loudspeaker under test) must be present. The minimum number of periods that are needed to detect a normal load is 5. ● The delay from 6 to 7 can be selected by software, starting from 1ms. Start Address byte with D0 = 0 ACK IB1 with D6 = 1 ACK IB2 ACK STOP Start Address byte with D0 = 1 ACK DB1 ACK DB2 ACK DB3 ACK DB4 ACK STOP Start Address byte with D0 = 0 ACK IB1 ACK IB2 ACK STOP X000000X XXX1X0XX Start Address byte with D0 = 0 ACK IB1 ACK IB2 ACK STOP X0XXXXXX XXX0XXXX Start Address byte with D0 = 0 ACK IB1 ACK IB2 ACK STOP XX1XX11X XXX1X0XX Start Address byte with D0 = 1 ACK DB1 ACK DB2 ACK DB3 ACK DB4 ACK STOP Start Address byte with D0 = 0 ACK IB1 ACK IB2 ACK STOP XX01111X XXX1X1XX Start Address byte with D0 = 1 ACK DB1 ACK DB2 ACK DB3 ACK DB4 ACK STOP |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |