| Electronic Components Datasheet Search |
|
STM32F407IG Datasheet(PDF) 70 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STM32F407IG Datasheet(HTML) 70 Page - STMicroelectronics |
|
70 / 167 page ![]() Electrical characteristics STM32F405xx, STM32F407xx 70/167 Doc ID 022152 Rev 2 5.3.6 Supply current characteristics The current consumption is a function of several parameters and factors such as the operating voltage, ambient temperature, I/O pin loading, device software configuration, operating frequencies, I/O pin switching rate, program location in memory and executed binary code. The current consumption is measured as described in Figure 19: Current consumption measurement scheme. All Run mode current consumption measurements given in this section are performed using a CoreMark-compliant code. VBOR1 Brownout level 1 threshold Falling edge 2.13 2.19 2.24 V Rising edge 2.23 2.29 2.33 V VBOR2 Brownout level 2 threshold Falling edge 2.44 2.50 2.56 V Rising edge 2.53 2.59 2.63 V VBOR3 Brownout level 3 threshold Falling edge 2.75 2.83 2.88 V Rising edge 2.85 2.92 2.97 V V12 1.2 V domain voltage(2)(3) VOS bit in PWR_CR register = 0 1.08 1.14 1.20 V VOS bit in PWR_CR register = 1 1.20 1.26 1.32 V VBORhyst (3) BOR hysteresis - 100 - mV TRSTTEMPO (3)(4) Reset temporization 0.5 1.5 3.0 ms IRUSH (3) InRush current on voltage regulator power-on (POR or wakeup from Standby) - 160 200 mA ERUSH (3) InRush energy on voltage regulator power-on (POR or wakeup from Standby) VDD = 1.8 V, TA = 105 °C, IRUSH = 171 mA for 31 µs -- 5.4 µC 1. The product behavior is guaranteed by design down to the minimum VPOR/PDR value. 2. The average expected gain in power consumption when VOS = 0 compared to VOS = 1 is around 10% for the whole temperature range, when the system clock frequency is between 30 and 144 MHz. 3. Guaranteed by design, not tested in production. 4. The reset temporization is measured from the power-on (POR reset or wakeup from VBAT) to the instant when first instruction is read by the user application code. Table 16. Embedded reset and power control block characteristics (continued) Symbol Parameter Conditions Min Typ Max Unit |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |