| Electronic Components Datasheet Search |
|
AS8222 Datasheet(PDF) 28 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS8222 Datasheet(HTML) 28 Page - ams AG |
|
28 / 43 page ![]() AS8222 Datasheet - Detailed Descr i p ti on www.ams.com/eng/FlexRay/AS8222 Revision 1.0 27 - 42 7.11.1 Error Pin Signalling In Table 20 the signaling at the Error Not (ERRN) pin is shown. 7.12 Loss of Ground In case the ground of the device is disconnected and the host pins are open the bus lines are switched to Idle_HZ. 7.13 ERROR Flags Description All error flags are reset after error readout is completed (see Section 7.15) or in POWER-OFF mode. 7.13.1 Undervoltage Detected VBAT Flag This flag is set if an undervoltage event at VBAT is detected. This flag signals if undervoltage was detected but will not initiate a mode change. 7.13.2 Undervoltage Detected VIO Flag This flag is set if an undervoltage event at VIO is detected. This flag signals if undervoltage was detected but will not initiate a mode change. 7.13.3 Undervoltage Detected VCC Flag This flag is set if an undervoltage event at VCC is detected. This flag signals if undervoltage was detected but will not initiate a mode change. 7.13.4 Bus Error The bus error flag is set, after a time tBUS_INHIB while the driver is enabled and activated until the end of the frame if 2 consecutive rising edges at the TxD pin without any rising edge at the RxD pin are detected, or 2 consecutive falling edges at the TxD pin without any falling edge at the RxD pin are detected. The flag is only set in NORMAL mode. 7.13.5 Bus Open Line BP open line can only be set in NORMAL mode if the driver is enabled. The flag is set if the absolute current through BP or BM is lower than ITHL for a time longer than tBUS_ERROR. The flag is meaningful only if no short circuit flag is set. 7.13.6 BP Short Circuit to VCC BP short circuit to VCC can only be set in NORMAL mode if the driver is enabled. The flag is set if the absolute current flowing through BP is higher than ITHH during transmission of Data0 for a time longer than tBUS_ERROR. Table 20. Error Not (ERRN) Signalling Supply undervoltage Flag at VBAT, VIO, VCC Remote Wake Flag Local Wake Flag Host Command ERRN STBN EN LX X H H NOT [Error flag] LH X H L L LH X H ↑ (positive edge) L → NOT [Error flag] LL X H L H LL X H ↑ (positive edge) H → NOT [Error flag] LL L L X H LL ↑ (positive edge) LX H → L L ↑ (positive edge) LL X H → L LH ↑ (positive edge) LX L L ↑ (positive edge) HL X L HX X X X L |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |