9 / 18 page ![]() 4-112 caler that supplies a once-a-second pulse to the counters. The seconds counter divide the pulse by 60 and its output clocks the minute counter every 60 seconds Further division by the minutes, hours, day of month and month counters result in 5 counters holding data that reflect the time/calendar from sec- onds to months. The counters are addressed separately and BCD data is transferred to and from via the data bus. The most significant bit of the hours counter (Bit 7) is user programmed to indicate AM or PM and will be inverted every 12th hour. (0=AM, 1=PM). Bit 6 of the hours counter is user programmed to enable the hours counter for 12 or 24 hour operation. (0=24,1=12). If 24-hour operation is selected, the AM-PM bit is “don't care”, but still toggles every 12th hour. Writing to the sec- onds counter resets the last 7 stages of the prescaler, allowing time accuracy to approximately 1/100 of a second. The most significant bit of the month counter is a Leap Year bit. If it is set to “1”, the counter will count to February 29, then roll to March 1. If set to “0” it will go to March 1st after February 28th. Alarm And Interrupt Status Register The alarm circuit consists of 1) seconds, minutes and hour alarm latches that hold the alarm time, 2) the outputs of the seconds, minutes and hour counters, and 3) a comparator that drives an interrupt output. The comparator senses the counter and alarm latch values and activates the interrupt output (active low) when they are equal (see Figure 3). The write-only alarm latches have the same addresses as their comparable counters. Bit 3 in the control register deter- mines data direction to the latches or counters and alarm enabling. For example, during a write cycle, if bit-3 in the control register is a “1”, addressing the seconds counter or alarm latch will load the seconds alarm latch from the data bus and will enable the alarm function. Conversely, if bit-3 in the control register is a “0”, addressing the seconds counter or alarm latch during a write cycle will place the value on the data bus into the seconds counter and will disable the alarm function. The interrupt output can be activated by the alarm circuit or the clock output. When an interrupt occurs, the RESET AM - PM AND HOUR LOGIC PRESCALE OSCILLATOR SECOND XTAL XTAL MINUTE HOUR DAY MONTH FREEZE CIRCUIT CALENDAR LOGIC PRESCALE SELECT CLOCK SELECT CONTROL REGISTER INT. STATUS REGISTER CLOCK AND INT. LOGIC CLOCK OUT INT VDD VSS I/O INTERFACE SECOND LATCH MINUTE LATCH HOUR LATCH COMPARATOR DB0-DB7 A0 A1 A2 TPA IO/MEM TPB/WR RD CS POWER DOWN ADDRESS DECODE AND CONTROL LOGIC 8-BIT DATA BUS FIGURE 4. FUNCTIONAL DIAGRAM - CONTROL REGISTER HIGHLIGHTED CDP1879, CDP1879C-1 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |