Electronic Components Datasheet Search
  English  ▼

X  

UPC3202 Datasheet(PDF) 5 Page - NEC

Part # UPC3202
Description  FREQUENCY DOWN CONVERTER FOR VHF to UHF BAND TV/VCR TUNER
PDF  20 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  NEC [NEC]
Direct Link  http://www.nec.com/
Logo NEC - NEC

UPC3202 Datasheet(HTML) 5 Page - NEC

  UPC3202 Datasheet HTML 1Page - NEC UPC3202 Datasheet HTML 2Page - NEC UPC3202 Datasheet HTML 3Page - NEC UPC3202 Datasheet HTML 4Page - NEC UPC3202 Datasheet HTML 5Page - NEC UPC3202 Datasheet HTML 6Page - NEC UPC3202 Datasheet HTML 7Page - NEC UPC3202 Datasheet HTML 8Page - NEC UPC3202 Datasheet HTML 9Page - NEC Next Button
Zoom Inzoom in Zoom Outzoom out
 5 / 20 page
background image
Data Sheet P12151EJ3V0DS00
5
µµµµPC3202GR
ABSOLUTE MAXIMUM RATINGS (TA = 25°C unless otherwise specified)
Parameter
Symbol
Condition
Ratings
Unit
Supply voltage 1
VCC
6.0
V
Supply voltage 2
UB
6.0
V
Power dissipation
PD
TA = 80°C
*1
466
mW
Operation temperature range
TA
–20 to +80
°C
Storage temperature range
Tstg
–55 to +150
°C
*1
Mounted on 50
× 50 × 1.6 mm double cupper epoxy glass board.
RECOMMENDED OPERATING RANGE
Parameter
Symbol
MIN.
TYP.
MAX.
Unit
Supply voltage 1
VCC
4.5
5.0
5.5
V
Supply voltage 2
UB
4.5
5.0
5.5
V
Operation temperature range
TA
–20
+25
+80
°C
ELECTRICAL CHARACTERISTICS (TA = 25°C, VCC = 5 V, fosc = fRF + 45 MHz, fIF = 45 MHz, POSC = –10 dBm)
Parameter
Symbol
Test Conditions
MIN.
TYP.
MAX.
Unit
Circuit Current 1
ICC1
@VHF, no input signal
*1
34.0
41.0
48.0
mA
Circuit Current 2
Icc2
@UHF, no input signal
*1
34.0
41.0
48.0
mA
Conversion Gain 1
CG1
fRF = 55 MHz, PRF = –30 dBm
*2
22.0
25.0
28.0
dB
Conversion Gain 2
CG2
fRF = 200 MHz, PRF = –30 dBm
*2
22.0
25.0
28.0
dB
Conversion Gain 3
CG3
fRF = 470 MHz, PRF = –30 dBm
*2
22.0
25.0
28.0
dB
Conversion Gain 4
CG4
fRF = 470 MHz, PRF = –30 dBm
*2
26.0
29.0
32.0
dB
Conversion Gain 5
CG5
fRF = 800 MHz, PRF = –30 dBm
*2
26.0
29.0
32.0
dB
Noise Figure 1
NF1
fRF = 55 MHz
*3
−
10.5
13.0
dB
Noise Figure 2
NF2
fRF = 200 MHz
*3
−
10.5
13.0
dB
Noise Figure 3
NF3
fRF = 470 MHz
*3
−
10.5
13.0
dB
Noise Figure 4
NF4
fRF = 470 MHz
*3
−
9.5
12.0
dB
Noise Figure 5
NF5
fRF = 800 MHz
*3
−
10.0
13.0
dB
Maximum Output Power 1
PO(SAT)1
fRF = 55 MHz, PRF = 0 dBm
*2
4.0
6.0
−
dBm
Maximum Output Power 2
PO(SAT)2
fRF = 200 MHz, PRF = 0 dBm
*2
4.0
6.0
−
dBm
Maximum Output Power 3
PO(SAT)3
fRF = 470 MHz, PRF = 0 dBm
*2
4.0
6.0
−
dBm
Maximum Output Power 4
PO(SAT)4
fRF = 470 MHz, PRF = 0 dBm
*2
4.0
6.0
−
dBm
Maximum Output Power 5
PO(SAT)5
fRF = 800 MHz, PRF = 0 dBm
*2
4.0
6.0
−
dBm
*1
By measurement circuit 1
*2
By measurement circuit 2
*3
By measurement circuit 3



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com